Honda CRF450R Manual Del Propietario Y Guía De Competiciones página 51

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 707
Subframe
7. Make sure the air cleaner connecting tube tab
(11) aligns with the air cleaner connecting tube
clamp hole (12).
(11)
(12)
(11) air cleaner connecting tube tab
(12) air cleaner connecting tube clamp hole
8. Tighten the screw (13) on the air cleaner
connecting tube clamp to the specified torque:
0.7 N·m (0.1 kgf·m, 0.5 lbf·ft)
Check the distance between the band ends is
4.5 ± 1.5 mm (0.18 ± 0.06 in).
(13)
4.5 ± 1.5 mm
(0.18 ± 0.06 in)
(13) screw
42
Servicing Your Honda
9. Hook the fuel tank band (14).
Install the ECM mounting rubber (15) to the
ECM bracket (16).
(14)
(16)
(15)
(14) fuel tank band
(15) ECM mounting rubber
(16) ECM bracket
10. Connect the IAT sensor connector (17).
(17)
(17) IAT sensor connector
11. Remove the old gasket from exhaust pipe.
12. Install the muffler clamp (18) and a new gasket
(19) to the exhaust pipe (20).
(18)
(19)
(20)
(18) muffler clamp
(20) exhaust pipe
(19) gasket (new)
13. Install the muffler (21).
14. Install the muffler clamp (18) by aligning the
tab (22) of the muffler clamp with the cutout
(23) of the muffler.
(18)
(21)
(23)
(18) muffler clamp
(22) tab
(21) muffler
(23) cutout
(22)