Roger Technology B70/2B Instrucciones Y Advertencias Para El Instalador página 57

Ocultar thumbs Ver también para B70/2B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 122
Door open indicator / photocell test function and "battery saving"
open.
Set
if the output SC
Set to
if the output SC
to terminal SC to reduce battery consumption.
Set to
if the output SC
Setting deceleration during opening
Setting deceleration during closing
01= the door decelerates near the limit switch
...
05= the door decelerates long before the limit switch.
Setting door closed position
The value set must ensure that the door is closed correctly after the limit switch is activated.
Warning!
sively low values cause the door to reverse (open) when it reaches the door closed stop.
Motor revolutions.
Setting pressure against door closed stop
N.B.
reduces the torque applied by the motor to prevent the structure of the overhead door from bending
or straining.
Warning! This parameter must be set in relation to the type of door installed and the mounting used
for the gear motor.
If this parameter is not set correctly, the automation system may not function properly and may
caused structural damages.
00= minimum force...09= maximum force.
Partial opening adjustment (%)
N.B.
From 10% to 85% of total door travel.
Setting automatic closing time
the door closes automatically. The timer count restarts if a photocell is triggered.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.
Setting reverse time after activation of sensing edge or obstacle detection
(crush prevention)
This sets the reverse manoeuvre time after activation of the sensing edge or the obstacle detection
system.
From 0 to 30 s.
Enable electric lock
Disabled.
Enabled. The electric lock is activated for a period of 3 seconds 0.5 seconds before the start of the
the electric lock.
57

Publicidad

Tabla de contenido
loading

Tabla de contenido