16
Mechanical release
Activating one of the two limit switches immediately reacquires the position.
17
Position recovery mode
• The door starts a low speed manoeuvre.
•
• The control unit recovers the installation data during this procedure. Warning
controls until one of the two limit switches is reached.
• Activating one of the two limit switches immediately reacquires the position.
18
Initial testing
• Turn on the power supply.
• Check that all connected controls are working correctly.
• Check travel and deceleration.
• Check that the impact force is correct in accordance with EN 12453 and EN 12445 Standards.
• Check that the safety devices are activated correctly.
•
•
and when closed.
•
the limit switch must be activated when the door is close to the door closed stop (at a distance no greater than 5
• Check that the door closes completely and does not push with excessive force against the door closed stop.
19
Maintenance
Check cleanliness and function.
and the housing.
Repeat the initial installation test procedure after cleaning.
Check that the battery is in good working order.
20
Disposal
removing the product correctly and safely. This product consists of numerous different materials. Some of
waste management facilities indicated by local legislation applicable for this category of product.
Do not dispose of this product as domestic refuse. Observe local legislation for differentiated refuse
Warning! Some parts of this product may contain substances that are harmful to the environment or dangerous and
which may cause damage to the environment or health risks if disposed of incorrectly.
66