3.

Safe handling

CAUTION
Federal law restricts this device to sale by, or on order of a physician!
Risk of injury and material damage if this product
is not used as intended!
Use the product only for its intended purpose.
WARNING
Risk of injury and damage to property due to
improper handling of the product!
Follow the instructions for use of all products
WARNING
used.
General risk factors associated with surgical procedures are not
described in this documentation.
It is the operating surgeon's responsibility to ensure that the surgical
procedure is performed correctly.
The operating surgeon must have a thorough understanding of both the
hands-on and conceptual aspects of the established operating tech-
niques.
Remove the transport packaging and clean the new product, either
manually or mechanically, prior to its initial sterilization.
Prior to use, check that the product is in good working order.
Follow TA022450 "Notes on electromagnetic compatibility (EMC) for
Acculan
components",
https://extranet.bbraun.com
To prevent damage caused by improper setup or operation, and in order
not to compromise warranty and manufacturer liability:
– Use the product only according to these instructions for use.
– Follow the safety and maintenance instructions.
– Only combine Aesculap products with each other.
Ensure that the product and its accessories are operated and used only
by persons with the requisite training, knowledge, or experience.
Keep the instructions for use accessible for the user.
Always adhere to applicable standards.
Ensure that the electrical installation of the room is consistent with the
requirements of IEC/DIN EN.
Do not operate the product in explosion-hazard areas.
Sterilize product before use.
When using the ECCOS fixation system, adhere to the appropriate
instructions for use for TA009721, see Aesculap Extranet at
https://extranet.bbraun.com
4
see
Aesculap
Extranet
4.

Product description

4.1

Scope of supply

Art. no.
Designation
GA334
Reciprocating saw
GA678
Sterile funnel
TA014545
Instructions for use of reciprocating saw GA334 (flyer)
4.2

Components required for operation

NiMH battery long GA676 (charged)
Sterile funnel GA678
Lid GA675
Support foot GB436R (as required)
Saw blade
4.3

Operating principle

The product 1 contains an electric motor, which is powered by a replace-
able battery 7.
The charged non-sterile battery 7 is inserted into the product 1 via the
sterile funnel 6 and sealed with the lid 8 so that it is sterile.
The oscillation frequency is controlled electronically and can be continu-
at
ously regulated with the trigger 2.
The product 1 has a coupling 14, which allows for the attachment of var-
ious saw blades 11. These saw blades 11 lock automatically when
attached to the product 1.
The saw blade 11 can be removed by activating a rotating sleeve 12.
The product 1 has an interface, which allows for the attachment of sup-
port foot 16.
5.

Preparation

Aesculap assumes no liability if the following rules are not followed:
Do not use products from open or damaged sterile packaging.
Prior to use, inspect the product and its accessories for any visible dam-
age.
Use the products and their accessories only if they are in perfect tech-
nical condition.