8. CONTROL

The Nano Air 50 is controlled using a remote control or by buttons located on the fan unit.
The buttons have limited functions: they can activate the second or third speed and set three out of the four ventilation modes. The remote
control has many more functions. The wireless remote control has a maximum range of about 2 metres. Pressing for up to 5 seconds is
necessary to validate each action.
The user must point the remote control towards the device's IR cell at the bottom right of the fan unit for it to work satisfactorily. If there is a
power cut, the unit will restart in its pre-cut mode.
1. Device on/o
Speed selection
Passive supply
The device louvres are open, the fan is not
running.
Exhaust*
The Nano Air exhausts or supplies air at the
desired speed, according to the position of
jumper CN7.
Humidity level adjustment
*When the Nano Air are connected in series, they run according to the position of the jumpers to adjust the ventilation mode on the control board.
Please refer to how to set the control mode on page 10.
28
Commutateur
Commutateur
Commutateur
Commutateur
de vitesse
de vitesse
de vitesse
de vitesse
Commutateur
Commutateur de mode
Commutateur de mode
Commutateur de mode
Speed switch
de vitesse
Commutateur de mode
de ventilation
de ventilation
de ventilation
Commutateur
de ventilation
Commutateur de mode
de vitesse
Ventilation mode switch
de ventilation
Commutateur de mode
de ventilation

Wireless remote control

Third speed
Fan deactivated
The device is not running. The louvres are closed.
Second speed
"Exhaust" mode
The ventilation unit runs in ventilation or air intake mode at the desired speed.
"Heat recovery ventilation" mode
The Nano Air switches every 70 seconds between ventilation mode and air intake
mode. The heat is recovered in this mode.
"Supply" mode
When the Nano Air are connected in series, they run in ventilation mode,
regardless of the position of the partition CN7.
Night mode
The device switches to the first speed when the
lighting in the room is switched off at night.
Supply
The ventilation unit supplies the room with fresh
air constantly (regardless of the position of jumper
CN7).
Heat recovery ventilation
The device switches between Exhaust and Supply
modes every 70 seconds.
The heat is recovered in this mode.