II TRANSPORT AND COMMISSIONING
The manufacturer will not be held liable for personal harm and/or
damage to objects deriving from incorrect commissioning and/or
by failure to comply with work accident-prevention standards.
This lack of compliance causes the warranty to terminate.
These operations are reserved exclusively for authorised from
the manifacturer and qualified personnel.
1
PRELIMINARY INSPECTION
The machine is transported at the risk and peril of the customer. If you
notice any damage to the packaging, immediately inform the carrier.
Inform the carrier immediately after opening the package if the machine is
damaged even if a few days after delivery.
It is always preferable to accept goods SUBJECT TO CLEARANCE.
2
TRANSPORT AND STORAGE
Any transport of the machine must be carried out in compliance with the
regulations in force regarding the transport of flammable substances.
The handling of this machine
must be carried out with extreme
care and in compliance with the
regulations on the prevention of
accidents at work in force in the country
where it is installed. Wear personal
protective equipment (safety shoes,
gloves, etc.). Two or more persons are
required to move this machine safely.
Failure to do so may result in injury or
damage to the machine.
Storage temperature must be between 0 °C
and +50 °C (32 °F - 122°F), and humidity
must be between 30 and 95% with no dew
(fig.II/01).
Refer to the data sheet inside this manual to verify that the positioning
surface is compatible with the weight of the machine.
Check that the storage room is adequately ventilated and that, in the
presence of flame ignition sources (e.g. open flames, gas burners, electric
heaters, lit cigarettes, etc.), these are positioned at such a distance from the
machines not to be dangerous in the event of any refrigerant leaks.
It is recommended that the room be equipped with a gas leak detection
device of a type suitable for the refrigerant used (R290).
The device must be stored in such a way as to avoid mechanical damage. In
case of damage, contact the authorized technical assistance.
Open the packaging with the utmost caution, taking care not to smoke, use
open flames and/or any other source of flame ignition because, in case of
anomaly, there could be an explosive atmosphere inside the packaging
itself.
Have a dry powder or CO
fire extinguisher available.
2
Once the appliance has been unpacked, the packaging must be kept in a
dry place out of the reach of children. If stored properly, it can be reused if
the machine is moved.
3
COMMISSIONING PLACE, POSITIONING
The handling of this machine must be carried out with extreme care
and in compliance with the regulations on the prevention of
accidents at work in force in the country in which it is installed. If
necessary, equip yourself with personal protective equipment (safety
shoes, gloves, etc.). Two or more persons are required to safely move this
machine. Failure to comply may result in personal injury or machine
damage.
For Indoor Use Only: This machine is designed to operate indoors under
normal ambient temperatures of 16 °C e 32 °C (61 °F - 90 °F).
The freezer has successfully performed in high ambient temperatures of
G5 G10
FRIGOMAT
fig.II/01
M04.37562 R.2021.10.23
104 °F (40 °C) at reduced capacities.
Humidity must be between 30 and 85% with
no dew (fig.II/02).
Install the machine in places that are not
excessively ventilated, protect it against
drafts and avoid direct sunlight.
Make sure the appliance is positioned on a
solid, stable, flat and levelled surface.
Refer to the data sheet inside this manual to
verify that the positioning surface is
compatible with the weight of the machine.
Check that the room is adequately
ventilated and that, in the presence of flame ignition sources (e.g.
open flames, gas burners, electric heaters, lit cigarettes, mobile phones,
etc.), these are positioned at such a distance from the machines not to be
dangerous in the event of any refrigerant leaks.
Have a dry powder or CO
fire extinguisher available.
2
Check that the place where the machine is installed is correctly illuminated.
It is mandatory to position the machine far away from equipment which
emits electromagnetic radiation which could cause its malfunctioning.
Install the machine in areas where use and maintenance is possible only by
trained personnel. Failure to comply with this requirement may lead to
physical damage or machine failure.
Caution: Keep ventilation openings in the appliance enclosure
or built-in structure free from obstructions.
4
COMMISSIONING
This machine should be installed in accordance with the
existing local codes. Please contact your local authorities.
Caution: Do not damage the refrigerant circuit. During commis-
sioning, do not pierce or heat with a flame the refrigerant circuit
at any point or damage the external parts as they could cause
refrigerant gas leaks. In case of damage, do not use and contact
the authorized technical assistance.
4.2 Electrical connections
Each machine must be connected to a power line dedicated to sanitary
power, a standard and in perfect working order.
Check the exact correspondence between the voltage and power of the
mains compared to the values carried on the data plate applied on the side
of the panel.
Connect the machine to the electrical power supply system.
Install a omnipolar master switch upstream the appliance with
minimum contact opening of 3 mm of adequate power, with a fuse and
circuit breaker protective system / automatic differential circuit
breaker.
The cable must be well laid, without being rolled-up or overlapped. It must
not be exposed to blows or tampering. It must not be in the vicinity of liquids
or water and heat sources. It must not be damaged in any way. If so, before
connecting the machine to the mains, have it replaced by qualified
personnel with another having suitable section and type 3Gx1,5 H05VV-F.
For safety purposes, make sure the earthing system to which the machine
plug is connected is compliant with standards and perfectly efficient. Failure to
comply may result in electrocution.
If needed, carry out an equipotential bonding, using the screw placed on the
rear of the machine below the frame and marked with the symbol shown in
figure (fig.II/03).
Do not use, for connecting the machine: extensions,
multiple sockets, adapters, etc.
4
for the technician
EN
fig.II/02
fig.II/03