withstand the loads transmitted during ope-
ration. The surface must have a load-carrying
capacity of at least 500 kg/m
Ambient working conditions
- Relative humidity 30% ÷ 95% without con-
densation.
- Temperature 0°C ÷ 50°C.
WARNING
Use of the machine in a potentially explosive
atmosphere is not permitted.
ELECTRICAL AND PNEUMATIC
CONNECTIONS
WARNING
Any connections to the workshop electrical panel
are the customer's responsibility, and must be
made by staff qualified in accordance with the
relevant legal requirements.
Before connecting the air supply system, make
sure the machine is set up as in fig. 4:
Pedal 13 fully up, column forward.
- The electrical supply must be suitably sized
in relation to:
the corresponding machine data plate;
the power supply hook-up point, so that
voltage drops under full load do not
exceed 4% (10% during start-up) compa-
red with the rated voltage specified on
the data plate.
- User must:
in compliance with the relevant safety
standards;
connection - A fig. 5 - and fit a differential
safety circuit-breaker with 30 mA residual
current;
User Manual S 100 PL
.
2
13
B
as indicated on the general wiring diagram in
this manual;
the workshop electrical system.
4
A
5
53