Column does not tilt
Column tilting cylinder faulty.
No air supply to cylinder.
Clamping arm cylinders leak air
Faulty piston or gaskets.
Column tilts violently or too slowly
Incorrect release valve setting.
valve.
Tyre pressure gauge needle fails to
return to 0
Pressure gauge faulty or damaged.
Wheel lifter not working
Control out of operation.
Rises slowly or has insufficient force.
board.
Cylinder leaking air.
WARNING
The "Spare parts" handbook does not
authorise users to carry out work on the
machine with the exception of those ope-
rations expressly described in the user
manual. It only enables users to provide the
technical assistance service with precise
information in order to minimise delays.
User Manual S 100 PL
WIRING DIAGRAM
Table codes 4-104805A
AP1
Single / two-speed motor circuit
board
M1
Motor
SQ1
Two-speed micro-switch
SQ2
Micro-switch (CLOCKWISE rotation)
SQ3
Micro-switch (ANTICLOCKWISE
rotation)
XB1
Connector
PNEUMATIC SYSTEM
DIAGRAM
Table code 4-106546
A – B - CONTROL FOR BEAD BREAKER
CYLINDER AND PENETRATION CYLIN-
DER FOR UPPER AND LOWER BEAD
BREAKERS
1.
Bead breaker cylinder
2.
Valve 5/3 NC
3.
Silencer filter
4.
Valve 3/2 NO
5.
Penetration cylinder
C – BEAD BREAKER LOCKING CONTROL
6.
Valve 3/2 NC
7.
Upper unlocking cylinder
8.
Lower unlocking cylinder
D – BEAD BREAKER COLUMN LOCKING
CONTROL
9.
Valve 3/2 NC
10.
Unlocking cylinder
E - COLUMN TILTING CYLINDER CON-
TROL
11.
Valve 5/2 NO
12.
Tilting cylinder
F - TOOL DRIVE CYLINDER CONTROL
13.
Valve 5/2 NO
14.
Tool drive cylinder
G – INFLATION PEDAL
89