After eight hours of inactivity (without any keys being pressed), the password will be automatically reactivated anyway.
The password status is always visible, as it is represented with a special page on the homepage; see paragraph 3.2.
The factory value of the password is "0". See also the list of factory values in chapter 8.
If the password is lost, there are two possibilities for editing the parameters of the device:
•
Make a note of all the parameter values and reset the device the factory values (see par. 8.1). The reset operation deletes all the device
parameters, including the password, and thus re-enables the system.
•
Apply to your service centre to receive a code to unlock the device.
6.2.2
Set Points 1-4
The parameters associated with the keys from "SET1" to "SET4" can be viewed and
changed under this menu item, through the page shown on the screen.
The first choice to make is whether you want the setpoints "SET1-4" to set the system
regulation mode to "Flow" or "Speed %" (see paragraph 5.1.1).
To do this, go to the first parameter shown at the top of the page, press "ENTER" and
make the section with the right and left arrow keys, then press "OK" to confirm.
This selection, which is unique for the setpoints 1-4, also modifies the setpoint units of
measure, which become respectively:
/h" with settable values between 5 and 25 m
-
in Flow: "m
3
-
in Speed: "%" (percent), with settable values between 20% and 100%.
The units of measure and the values assigned to the setpoints (indicated with S1 - S4) are clearly shown on the screen.
To change them, move with the arrows onto the value to be changed, press "ENTER" and change the value with the vertical arrows; press "OK" to
confirm the change and move on to the next values.
Each set point has its own duration, indicated on the display with the symbols T1 - T4 and settable between 10 minutes and 18 hours, or
"ENDLESS".
The values T1 - T4 are changed in the same way as described above.
The duration value indicates the time that the setpoint remains active, after which it ends; if you want the setpoint to remain always
active without interruption, the duration must be programmed as "ENDLESS".
The factory values are given in chapter 8.
6.2.3
Set Points 5-8
This menu items allows you to view and change the parameters associated with the
setpoints from 5 to 8.
The setpoints from 5 to 8 cannot be loaded from the keyboard, but they are activated and
deactivated only by the TIMERS system (paragraph 6.2.5). Unlike setpoints 1-4, they do not
have any associated duration, as the activation time is decided always and only by the
TIMERS.
Like the setpoints 1-4, here too you choose the regulation mode by flow or speed (see paragraph 5.1.1) and the setpoint values,
indicated with S5 – S8.
The procedure for selection and changing is identical to the one described in the previous paragraph. The factory values
are given in chapter 8.
To simplify the use of the Timers, it is recommended to assign increasing values to the setpoints, from Setpoint 5 to Setpoint 8 (see
par. 6.2.3 and following).
6.2.4
Quick Clean
The "QuickClean" key allows you to perform a rapid wash of the system or fast recirculation, for
example by cleaning, suction, adding chemicals, and so on.
Its parameters are:
-
setpoint in Speed %, settable between 20% and 100%;
-
duration (execution time), settable between 1 minute and 10 hours.
The factory values are: maximum curve 100%, for ten minutes (see also chapter 8).