1-
User panel cover
2-
User panel
3- QR code
4- Quick guide
5- Terminal board cover
6- External connector
7‐ Power cable inlet
1.2
Technical characteristics
The technical characteristics are summed up in the table below.
Topic
ELECTRIC POWER
SUPPLY
CONSTRUCTION
CHARACTERISTICS
HYDRAULIC
PERFORMANCE
WORKING
CONDITIONS
1.3
SVRS Notes (Only applicable to model SVRS)
The Safety Vacuum Release System (SVRS) model is designed to provide an additional layer of protection against body suction entrapment.
SVRS model is designed to release body entrapment. It may mitigate evisceration or limb entrapment. It does not prevent hair, mechanical
entrapment. It complies with ASME/ANSI A112.19.17 -2010 SVRS standard.
1. SVRS devices shall only be installed in conjunction with an ASME A112.19.8 suction fitting, or a 12 in. x 12 in. (305 mm x 305 mm) drain
grate or larger, or an approved channel drain system at each suction outlet or drain outlet.
2. Check valves and hydrostatic valves shall not be used in suction systems protected by SVRS devices.
WARNING – The presence of a hydrostatic valve in the suction piping has been shown to prolong the high vacuum present at the
drain, even though the drain was protected by an SVRS device.
3. All SVRS devices shall be factory set or field adjusted to site -specific hydraulic conditions. Once installed, the system shall be tested by
simulating an entrapment event.
4. All SVRS devices are tested with a single functioning suction outlet.
5. A ball, butterfly, or sliding gate valve shall be installed within 2 ft. (0.6 m) upstream from the S VRS (between the SVRS and the protected
suction outlet), or a test mat shall be used to cover the suction outlet to simulate an entrapment event. There shall be three simulated
Parameter
Voltage
Frequency
Maximum current
Maximum power
Overall dimensions
Empty weight (excluding
packaging)
Protection class
Motor insulation class
Maximum head
Maximum flow rate
Maximum working pressure
Max liquid temperature
Max ambient temperature
Table 1 – Technical Characteristics
ENGLISH
Figure1
Figure 2
E-SWIM 150
220-240 V +/- 10%
50/60 Hz
5.6 SFA
1250 W
550 x 300 x 316 mm / 22.6 x 12.2 x
12.4 in
18 kg / 39 lb
IP55
F
16 m / 52 ft
32 m3/h / 141 gpm
2,5 bar – 36.2 psi
40°C / 104°F
50°C / 122°F
5
E-SWIM 300
220-240 V +/- 10%
50/60 Hz
10 SFA
2250 W
574 x 304 x 354 mm / 22,6 x 12 x
13,9 in
21,3 kg / 47 lb
IP55
F
26 m / 85,3
42,6 m3/h / 188 gpm
2,8 bar – 40.6 psi
40°C / 104°F
50°C / 122°F