Anti-Freeze
8
9
Anti-Lock
8.1
Restoring the factory settings
To reset the factory values, use the "Factory Settings" page of the "System" menu (par. 6.2.10).
Alternatively, switch off the device, wait until the display has switched off completely, press and hold down simultaneously the two keys "SET1"
and "SET4" and turn on the power; release the keys only when the messages appear on the display. This restores the factory settings (consisting
of a message and a rereading on EEPROM of the factory settings permanently saved in the FLASH memory and listed in the table above).
Once all the parameters have been set, the device returns to normal operation.
NOTE: this operation obviously deletes all the parameters that have previously been modified by the operator. Once the factory
values have been restored, it will therefore be necessary to reset all the parameters that characterise the system, as at the first
installation: for the sake of convenience, the system again proposes the WIZARD (paragraph 4.2).
9
TROUBLESHOOTING
9.1 General problems
The pump does not start (display off): No
electric power.
Check that there is voltage and that the connection to the power network is correct.
The pump is not sucking:
No water in the prefilter or clogged prefilter. Closed
valve in the pipes.
Air getting into the suction pipe.
The motor is not working:
The electric power supply or switch are turned off. Motor
electrical connections are faulty.
Impeller blocked by foreign bodies, shaft not turning.
Noisy pump:
Air getting into the suction pipe.
Presence of foreign bodies in the pump body.
Cavitation.
Ball bearing damaged.
Low flow rate: low pressure in the filter. Basket
or impeller clogged.
Air getting into the suction pipe.
Motor turning in the opposite direction.
Low flow rate: high pressure in the filter. Delivery
pipe choked.
Inadequate section of the power supply cables. Pump
filter clogged.
9.2
SVRS problems
The SVRS has tripped:
•
Verify if any entrapment occurred, taking action and providing first aid if needed.
After having checked nobody is entraped, the pump can be restarted automatically or by manual RESET.
False tripping of the SVRS:
•
function
speed
temperature
function
Table 6 – Factory (default) settings
ENGLISH
enabled
30%
4 °C
40 °F
enabled
(*) Factory value on some markets