Descargar Imprimir esta página

DAB E.SWIM Serie Instrucciones De Instalación Y Mantenimiento página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

Check the integrity of the pump.
WARNING: Pay attention not to damage the control panel and the electronic board cover. Damaging these two parts could
compromise the operation of the pump.
2.1
Hydraulic connections
Follow these recommendations with care:
 Install the pump horizontally, on a flat and sturdy base, as close as possible to the edge of the pool.
 The pump is able to overcome a maximum difference in level of 4 m (with non-return valve). NOTE: the non-return
valve cannot be used in systems with SVRS.
 Install the filter and the pump in a protected, well ventilated place.
 Avoid letting the motor be immersed in water.
 For pump-system connections use only adhesives suitable for plastics.
Provide adequate support for the suction and delivery pipes so that they do not weigh down on the pump.
 Do not make the couplings between the pipes too tight.
 Suction pipe diameter > = pump inlet diameter.
 If a metal pipe is connected, fit a plastic coupling on the pump inlet.
 The suction pipe must be perfectly airtight.
ATTENTION: before connecting the pipes, check that their inside is clean.
 ONLY FOR SYSTEMS WITHOUT SVRS PROTECTION: To avoid problems in suction, install a foot valve and make a
positive slope of the suction pipe towards the pump.
IMPORTANT: in systems protected with SVRS, neither non-return valves nor hydrostatic valves can be installed (they reduce the
efficacy of the protection).