2. An input for an external analog signal (between the IN1 and GND signals), configurable as 0-10V or
4-20 mA .
The following figure shows the relationship between the analog signal on input and the setpoint SP to be
activated.
See the following parts of this manual for further information on operation.
The inputs are not opto-isolated.
To connect to the input and output connector, use only the cable kit DAB.
Attention: keep the cable for the input and output signals well away from the power and alternate supply lines (230V and similar), so as
to limit disturbances and interference that can alter the signals.
When it is not in use, the connector on the pump must be kept accurately closed, with the cap well tightened. Only in this way is
the necessary resistance to water and damp guaranteed.