4
COMMISSIONING
4.1
Priming
Self-priming can take at least 9.5 minutes to prime to 5 feet at setpoint 150%.
Installation below water level:
Fit one gate valve in the suction pipe and one in the delivery pipe to isolate
the pump.
Fill the pump, slowly and completely opening the gate valve in the suction
pipe, and keeping the gate valve on delivery open to let the air out.
Installation above water level:
If there are several suction pipes, arrange the pipes and the manifold below
water level and reach the pump with only one vertical pipe.
To reduce the priming time, it is recommended to install the pump with as
short a suction pipe as possible.
Fill the basket of the filter with water up to the level of the suction mouth.
It is recommended to set the sand filter in backwash mode to speed up
priming.
It is strongly recommended to install a check valve on the suction line
to facilitate the priming of the pump.
IMPORTANT: non-return valves cannot be installed in systems protected with
SVRS.
4.2
Guided configuration (WIZARD)
When switched on for the first time, the device proposes to perform the WIZARD easy configuration, which guides the user in a fast and easy
setting of the most important parameters.
It is necessary to perform the WIZARD: the initial system status is that of the factory configuration, and in that the language
and the units of measure may not be those used in your country, the weekly clock starts at a random time, and the other
parameters may not be suitable for your system.
If you need to revise all these parameters quickly at a later date, you can reload the WIZARD by selecting a specific item on
the menu (paragraphs 6.2 and 6.2.1.1).
The WIZARD presents the following pages in sequence:
1. Select Language (see also par. 6.2.1.2)
2. Select time display mode (24h or am/pm)
3. Set current time
4. Set current day
5. Set Unit of measure of head
6. Set Unit of measure of flow
7. Set Unit of measure of temperature
8. Select Regulating Mode with Keys SET1-SET4 (see also par. 5.1.1)
9. Select maximum limit of flow (Qmax) (see also par. 6.2.1.5)
10. Select maximum limit of head (Hmax)
11. Final confirmation
Each page of the Wizard presents a single parameter to configure, starting from the language.
Title
Keys to use
(the arrows are not shown)
ENGLISH
Figure 8
Figure 9
13
E.swim 150
Max 4m-13ft
E.swim 300
Max 1,5m-
4,9 ft
Page in the Wizard
(this is page 1 of a total of 11 pages)
Figure 10