"Manual" mode and "Auto" mode can also be used simultaneously; in this case, as will be described better below, the
automatism ("Auto") remains active in the background but, if necessary, it can be temporarily overridden by a manual
command, which has precedence.
5.2
Rapid starting and stopping of the pump ("Manual" mode).
The pump leaves the factory and is delivered with Priming enabled: if the programming of Priming is not changed (see par. 6.2.6), when
switched on for the first time, the pump may start at top speed.
Before pressing "RUN/STOP", make sure that the valves are open, the pipes are not blocked, and keep away from the filter and from
parts that can be pressurized.
Check well all the IMPORTANT SAFETY WARNINGS AND RECOMMENDATIONS.
Once the first configuration has been carried out with the WIZARD (in conditions with the white LED
starting the pump is very easy:
press the key from "SET1" to "SET4" corresponding to the desired setpoint (e.g. "SET1"), or the "QuickClean" key; the LED corresponding
•
to the key pressed lights up, indicating the selection made;
press "RUN/STOP".
•
At this point, switching on is enabled and the pump starts; the green running LED
(indicating that now the system is active).
The system performs startup: the pump starts at a fixed speed (50%) for a few seconds.
Startup is necessary for the pump to switch on correctly, and it is always performed at each start of the motor.
Priming is then performed (par. 6.2.6), if it is enabled (according to factory setting).
After that, the pump continues to run according to the setpoint associated with the "SETx" or "QuickClean" function used (in the example, the
"SET1" setpoint).
The factory values are given in chapter 8.
For the "SETx" keys, it is easy to change the setpoint (choosing also between flow or speed) and the other characteristics
(duration) by means of the menu (see 6.2.2).
Also the operation associated with the "QuickClean" key can be customized (see 6.2.4).
Pressing a "SETx" or "QuickClean" key puts the pump into "Manual" mode, which has precedence over "Auto" mode: even
with "Auto" active ("Auto" LED on), pressing a "SETx" or "QuickClean" key will start the pump with the setpoint associated
with the key.
An execution time or duration is also associated with each "SETx" function and with "QuickClean". The following events may occur while the
pump is running:
the end of the time (or duration) associated with the "SETx" or "QuickClean" key selected previously is reached,
•
or the same "SETx" or "QuickClean" key is pressed again;
•
in both cases, the key function ceases, its LED switches off, and the pump stops.
However, if the "Auto" function was active in the background ("Auto" LED lit), it now takes control of the machine, deciding either
to switch off the pump or to switch on with another setpoint, depending on the programming made. So the pump might not switch
off.
It is very easy to stop the pump manually: with the pump running, just:
•
press "RUN/STOP".
the pump thus stops in any case (*), interrupting all active modes (this means that also "Auto" mode, which may have been active in the background,
switches off); the green running LED
The SETx setpoint that was active remains if it had the duration "forever" ("ENDLESS"). Otherwise it is deactivated when it is
disabled with the "RUN / STOP" button, and its LED turns off.
When "RUN/STOP" is pressed again, the system is re-enabled; the white LED
(*) The only exceptions: the Antifreeze and Antilock functions start the pump even if the system is disabled (see paragraphs 6.2.7 and 6.2.8).
After a blackout during operation in Manual mode, the system does not restart unless the SETx key that was lit had the duration
"ENDLESS". In this case, the system restarts with the same setpoint as before. Auto mode returns to the status that it was (it is
activated if it was active before switching off).
5.3
Rapid changing of the setpoint and of the pre-set parameters
When the pump is running with a "SETx" key pressed (as described above):
•
pressing a "SETx" key different from the active one (e.g. "SET3", while "SET1", is active) will perform the setpoint of the new key (for the whole
respective duration) and the lighting of the LEDs changes accordingly;
ENGLISH
switches off. The white LED
lights up, while the white LED
starts to blink, indicating that the system has been disabled.
is lit with a steady light.
16
blinking and the "Auto" LED off),
is lit with a steady light