3.2
Main page of the display (homepage)
This is the appearance of the home page, which appears on the display in normal operating conditions and sums up all the information on
system operation.
The information forms three groups:
1.
The status lines (at the top) provide information on:
o
the status (running, stopped) along with the current
command (SET1 – SET3, QC, Timer A-H, etc.), or any
active Warnings and Faults; in the example in the figure:
"System Running" indicates that the system is active,
commanded by "TIMER A".
o
the active setpoint value ("SP") and the expected time of
the end of the active function ("End").
2.
The instantaneous values of the electrical and hydraulic magnitudes, which are
grouped in the space in the center of the screen and continuously updated during operation.
The appearance of the symbol (
value, based on current working conditions; the appearance of the symbol (
value, based on current working conditions.
3.
The rapid access bar (at the bottom): contains the date and time with some icons; you navigate on these elements with the right
arrow and left arrow keys, and move the selection (highlighted by the box), then press "ENTER" [
item.
This gives simple and direct access to the items used most frequently, without having to scroll through the menu. These are the
items available and the functions accessed:
"Configuration"
•
•
Current "Date and time" direct change of date and time (paragraph 6.2.1.3),
"Timer"
•
"External Control"
•
alternative to "Timer" when the external control function has been activated).
"Key"
•
symbol represents the current status:
In the case of a pump with SVRS, the homepage shows an additional indication when the pump is running (see figure below).
The figure on the left (where the message "SVRS INACTIVE" is flashing) shows one of the transitory moments when the SVRS is not yet active.
In this phase also the red fault LED
In the case shown in the figure on the right, on the other hand, the SVRS protection is active and ready, as indicated by the message "SVRS
READY" (lit with a steady light).
The up arrow symbol, next to the instantaneous power, indicates that a power limitation is in progress. The same symbol can appear in
front of other values in the case of active limitations (see paragraph 6.2.1.5).
) next to a parameter indicates that the parameter has reached its maximum
Menu access (see chapter 6),
displays the Timer activation table (paragraph 6.2.5.2),
displays the status of the external control (paragraph 6.2.5.3; this symbol is present as an
(or padlock) direct access to the protection system with Password, described in paragraph 6.2.1.8; the
(key) Password not entered, free access to all functions;
(closed padlock) Password entered and active, access to the control keys is prevented;
(open padlock) Password entered but temporarily deactivated, access is temporarily allowed.
) flashes.