instead, by pressing the up arrow and down arrow keys, you can increase of decrease the flow or speed (setpoint) at which the pump is
operating. The setpoint value is shown on the display on the homepage (see par. 3.2).
The modified value is stored automatically in the same "SETx" key currently selected (the one with the LED lit).
Also if "QuickClean" has been pressed and the pump is running, the setpoint can be changed with the arrow keys as described above; the new
value is saved directly in the "QuickClean" key.
Both a setpoint and an execution time (or duration) are associated with each "SETx" and "QuickClean" key. Unlike the setpoints,
the times cannot be changed with the quick method described above; however, they can be changed easily (see 6.2.2 and 6.2.4).
The factory values are given in chapter 8.
5.4
Advanced use ("Auto" mode)
On this machine there is a powerful and sophisticated system of timed starting at different setpoints, each with a different duration, which can be
planned as preferred on a weekly basis. A simple setting of the parameters is sufficient to perform all the desired cycles completely automatically
for seven days. This mode is called "Timers". (See par. 6.2.5)
It is also possible to have all the pump starts commanded by an external control unit or computer, connected to the input signals (described in
2.3.). This mode is called "EXT", or external (see par. 6.2.5.3). In this case the internal timers do not intervene.
These two modes make up the "Auto" mode.
It is disabled when the pump leaves the factory, because it must be configured specifically for each system (swimming pool, bathing pool, spa,
etc.).
To enable "Auto" mode, just go to the menu (par. 6) and, following the indications on the screen, choose the mode (Timers or Ext) and set the
values for your system.
After having programmed "Auto" mode, proceed as follows to activate it (in conditions with the white LED
•
with the pump stopped, press the "Auto" key (the LED next to the key lights up),
then press "RUN/STOP" (the white LED
•
From this moment, the pump starting operations, with their respective setpoints and operating times, will be decided automatically, without requiring
any further intervention by the operator.
Even with "Auto" mode active ("Auto" LED on), pressing a "SETx" or "QuickClean" key will start the pump immediately with the
setpoint and the duration associated with the key. The pump thus goes into "Manual" mode, which has precedence over "Auto"
mode. However, "Auto" mode remains active in the background and resumes control as soon as the function of the key that was
pressed ceases.
To deactivate "Auto" mode:
press the "Auto" key again (the LED next to the key lights up).
•
If you need to stop the pump manually when it is operating, just:
•
press "RUN/STOP".
the pump thus stops in any case (*), interrupting all the active modes.
This means that "Auto" mode stops and also any active manual mode ("SETx" or "QuickClean"); the green running LED
The white LED
starts to blink, indicating that the system has been disabled.
When "RUN/STOP" is pressed again, the system is re-enabled and everything restarts as before. The white LED
(*) The only exceptions: the Antifreeze and Antilock functions start the pump even if the system is disabled (see paragraphs 6.2.7 and 6.2.8).
6
SELECTING THE PREFERRED MODES (MENU)
A rapid and intuitive menu system gives access to the various modes, allowing you to activate and configure them as desired.
6.1
Menu access and navigation
The menu is accessed by pressing the "ENTER" key [
bottom of the homepage (par. 3.2).
The complete structure of the menu, with all the items of which it is composed, is shown in paragraph 6.2.
6.1.1
Appearance and opening page of the menu
When you enter the menu, the opening page appears, as in the figure:
ENGLISH
lights up with a steady light).
] when the item "Configuration"
17
blinking and the "Auto" LED off):
switches off.
is now lit with a steady light.
is selected in the bar at the