6.2.10 System
This menu item groups together a number of pages for the advanced user.
The "Info" page shows information about the operating status, totals and statistics (operating
hours, pumped volume, absorbed energy) and other data (such as firmware version, serial
number). The totals and statistics shown are overall and partial; the partial totals can be reset
(Reset) by the user (by holding down "OK" [
display).
The "Factory Settings" page allows the resetting of the factory values (see also paragraph
8.1).
The "Update" page allows the updating of the product firmware, which can be done via wireless using the special device "DAB E.sylink
7
PROTECTION SYSTEMS – LOCKS (FAULT)
The device is equipped with protection systems to preserve the pump, the
motor, the supply line and the inverter. If one or more protections trip, the
one with the highest priority is immediately notified on the display.
Faults cause switching off of the motor and lighting of the red warning LED
(
).
In some types of fault, the motor restarts as soon as normal conditions are
restored; in others, attempts at automatic reset are carried out after a certain
space of time.
It is also possible to try to cancel the error condition manually (see the
following paragraphs). If the error condition remains, you must take steps to
eliminate the cause of the fault.
7.1 Manual reset of error conditions
In block (fault) status, the user can cancel the current error and force a new
attempt by pressing and releasing the "Reset" key.
If the action is successful, the red warning LED(
system returns to normal operation. Instead, if the error condition remains,
you must take steps to eliminate the cause of the fault.
7.2 Automatic reset of error conditions
For some types of fault, automat reset attempts are contemplated. In particular
for:
-
e27
Dry operation
-
e28
Pump not primed
a new attempt is made after a few minutes, and repeated cyclically.
If an attempt is successful during the reset sequence, the sequence is interrupted, the red warning LED (
to normal operation.
In the case of the "Excess temperature" faults, the system resume operation as soon as the temperature returns within the normal operating
range.
For the error "e33 SVRS trip", see paragraphs 1.3 e 7
7.3
Viewing the block history
The list of the faults and blocks that have occurred most recently can be consulted under the menu item "Fault History". See paragraph
6.2.9.
8
FACTORY SETTINGS
The system leaves the factory with a series of preset parameters, which may be changed according to the requirements of the plant and of
the user. Each change of the settings is automatically saved in the memory.
The factory (or default) settings are summed up in the following table. You can make a note of the values modified for your own installation in the
"MEMO" column.
As indicated in the table, some default values may differ depending on the market for which the system is intended.
If desired, it is possible to restore the default settings, proceeding as described in paragraph 8.1.
ENGLISH
] for 3 seconds, as indicated on the
) goes out and the
27
Fault No.
Description on the display
e1 / e14
e15
Motor phases short circuit
e16
e17 / e19
e20 / e22
Electronic excess temperature
e23
e24
e25
Motor excess temperature
e26
e27
e28
e29
e33
Tripping of SVRS ("SVRS trip")
Table 5 – List of Faults
) goes out and the system returns
Figure 40
".
Internal error
Short circuit to earth
Internal error
Low mains voltage
High mains voltage
Motor blocked
Dry operation
Pump not primed
No current