Important
The connection must be made by authorised,
skilled personnel, in accordance with the re-
levant legal requirements, using appropriate
and specifi ed materials. The appliance is sup-
plied with operating voltage 230V1N 50 Hz (
60 Hz on request) .
For direct connection to the mains one must envi-
sage a device that ensures disconnection from the
mains, with a contacts opening distance that en-
sures complete disconnection in the conditions of
category III over-tension, in compliance with the
installation rules.
GB
Undo the screw (F) to remove the lid (G).Connect
)
the circuit-breaker (A) to the terminal board (H)
of the appliance as shown in the diagram and
in the electrical system diagram at the back of
the manual. Use a cable with at least H05RN-F
characteristics. Tighten the cable gland (L).
– Weight: ≥ than H05RN-F type (designation 245
IEC 57)
– Temperature of use: ≥ 80°
Tighten the cable gland (L).
)
Important
When connecting, take care to connect the
neutral and earth lines.
Replace all when the operation is complete.
)
_inst_GB
ELECTRICAL CONNECTION
C
A
Caution - Warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity
supply as follows:
If not already present, install a circuit-breaker
)
with overload cutout and residual current safe-
ty breaker close to the appliance:
Remove the knob (C).
)
Undo the screws (D) and remove the control
)
panel (E).
D
F
-
-
E
D
G
H
L
(A)
ENGLISH