Adjust the pressure using the screw (H) to suit
)
the type of gas being supplied, until the corre-
sponding value appears on the pressure gauge
(see injector table).
– Turn clockwise to increase the pressure.
– Turn anticlockwise to decrease the pressure.
Important
The nut (L) must be screwed fully down.
Check the stability of the fl ame.
)
Switch the burner off and back on a few ti-
)
mes to check that the setting has been made
correctly.
Switch off the burner, turn off the gas supply
)
tap and disconnect the pressure gauge.
Fully tighten the screw (E).
)
After making the setting, seal the screws (E-
)
H) with paint.
Replace the guard (G).
)
RADJUSTING BURNER PRIMARY AIR 2*1BR2G 2*1BR3G
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
)
Remove the knob (C).
)
Undo the screws (A) and remove the control
)
panel (B).
Undo the locking screw (D).
)
C
A
_inst_GB
Replace the control panel (D) and the knob
)
(B) on completion of the operation.
Set the bush (C) at the distance as shown in the
)
fi gure.
Tighten the screw (D). After making the setting,
)
seal the screw with paint.
Replace the control panel (B) and the knob (C)
)
on completion of the operation.
B
A
-
-
F
G
L
E
C
42±1
mm
D
H
GB
ENGLISH