Descargar Imprimir esta página

Angelo Po 1S1BR1G Manual De Uso página 159

Sartén de gas

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ADJUSTMENTS
INSTRUCTIONS AND WARNINGS FOR ADJUSTMENTS
WARNING: Before making any type
of adjustment, activate all the safety de-
vices provided and decide whether staff at
work and those in the vicinity should be in-
formed . In particular, close the the gas and
water supply taps, cut off the electricity sup-
ply using the master switch and prevent ac-
cess to all devices which might cause un-
expected hazards and damage to people's
health and safety if activated .
Natural and bottled gas
Proceed as follows .
Turn off the gas supply tap and switch
1)
off the main electricity supply .
Remove the knob (B) .
2)
Undo the screws (C) and remove the
3)
control panel
.
(D)
Undo the screw (E) of the pressure
4)
connection .
Connect the pressure gauge (F) to the
5)
pressure test point .
Turn the guard (G) anticlockwise and
6)
remove it .
Turn the gas supply tap back on and switch
7)
the main electricity supply back on .
Light the burner and turn the control knob
8)
(A) to the maximum temperature setting .
Turn the control knob (A) anti-clockwise to
9)
the lowest power setting . You will hear the
click as the device switches .
Adjust the pressure using the screw (H) to
10)
suit the type of gas being supplied, until the
corresponding value appears on the pressure
gauge (see injector table) .
– Turn clockwise to increase the pressure .
– Turn anticlockwise to decrease the pressure .
3413920_inst_GB
ADJUSTMENTS
ADJUSTING GAS VALVE MINIMUM SETTING
NOTE: This adjustment is only required
if the type of gas to be connected is differ-
ent from that used for testing after the con-
version procedure has been carried out (see
page 14) .
WARNING: Adjustments must be car-
ried out by authorised, qualified staff, in ac-
cordance with the relevant legal require-
ments .
B
C
F
ENGLISH
D
C
G
L
H
E
15

Publicidad

loading