Descargar Imprimir esta página

Angelo Po 1S1BR1G Manual De Uso página 50

Sartén de gas

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
Faults
The pilot light does not
ignite .
The pilot light ignites but
the burner remains off .
The flame is yellow .
Burner control knob is
stiff .
No water delivered .
24
Causes
The spark ignition devices
are not working .
Air in pipelines due to long
period out of use .
Burner dirty, heat exchange
pipes clogged, condensation
drips .
Gas valve malfunction .
Filler solenoid valve faulty .
Filling switch malfunction .
Well raised or not resting on
fixed part of appliance .
Remedies
Check that the ignition devices are
in good working order .
Light by hand with a naked light .
NOTE: Contact the after-
sales service .
Make more attempts to light the
flame .
Check the condition of the ther-
mostat and activate any ignition
enabling device .
NOTE: Contact the after-
sales service .
NOTE: Contact the after-
sales service .
Check the pressure switch connec-
tion .
NOTE: Contact the after-
sales service .
Check the water connection .
NOTE: Contact the after-
sales service .
Check that the well is not raised or
not resting firmly on fixed part of
appliance .
3413920_ut_GB
FAULT

Publicidad

loading