NOTE: The nut (L) must be screwed ful-
ly down .
Check the stability of the flame .
11)
Switch the burner off and back on a few
12)
times to check that the setting has been
made correctly .
Switch off the burner, turn off the gas sup-
13)
ply tap and disconnect the pressure gauge .
Fully tighten the screw (E) .
14)
After making the setting, seal the screws
15)
(E-H) with paint .
Replace the guard (G) .
16)
Replace the control panel (D) and the knob
17)
(B) on completion of the operation .
To carry out this operation, proceed as follows .
Turn off the gas supply tap .
1)
Remove the knob (C) .
2)
Undo the screws (A) and remove the control
3)
panel (B) .
Undo the locking screw (D) .
4)
C
A
16
RADJUSTING BURNER PRIMARY AIR
B
A
F
E
Set the bush (C) at the distance as shown in
5)
the figure .
Tighten the screw (D) . After making the set-
6)
ting, seal the screw with paint .
Replace the control panel (B) and the knob
7)
(C) on completion of the operation .