Overview
Model 85875 is a pumping unit designed to
operate a Centro-Matic lubrication system.
Unit includes a vent valve to relieve line
pressure to recharge injectors.
FlowMaster II rotary-driven hydraulic
pump includes pressure reducing valve,
flow control valve and solenoid operated
(24 V
) on/off valve. Pump is double
acting, dispensing lubricant on both "up"
and "down" strokes.
This unit is for use with SL-V, SL-1, SL-11,
SL-32 and SL-33 series injectors.
Product specifications
Operating working hydraulic pressure
Maximum output pressure
Hydraulic inlet flow
Pump ratio with manifold
Ambient operating temperature
Operating voltage
Hydraulic inlet port
Tank return port
Maximum hydraulic fluid temperature
Container capacity
*
Indicates change.
Dimensions
40°
20°
37.4 in
(950 mm)
*
Indicates change.
Fixed at 400 psi (28 bar)
3 500 psi (241 bar)
Up to 7 gal/min (27 l/min)
Approximately 10:1
–40 to +150 °F (–40 to +66 °C) *
24 V
SAE 4
SAE 6
250 °F (121 °C)
90 lbs (40,9 kg)
6
20.46 in
(520 mm)
Table 1