Under Relay board, one of the following functionalities can be set for each of the
4 terminals, viewed from left to right:
Aquamatic control
-
-
-
-
Charging
Charge 50%
Charge 80%
Charge Finish
Main Charge Finished
-
Charge Not Complete
-
-
Charge OK
-
Common Error
-
-
-
Common Error + Warning
-
Signal Lamp
-
-
Immobilizer Device
ON
-
Refill Indicator
-
-
Battery Cold
External Air Pump
-
64
Signal, e.g. for actuating a solenoid valve
"Standard" program with settings pre-configured at the factory
"User" program with user-defined setting options
For more information on the Aquamatic control, see the "Aquamatic control"
section of the "Options" chapter.
Signal when main charging phase is finished
Signal if the battery is prematurely disconnected from the battery charger
Can be set from 1 to 10 s
Battery is being charged or is already fully charged
Signal in the event of an error
A power failure can be displayed as an error ("ON" setting).
If the device is in an error state, a freely defined text can be displayed, which
can contain the contact details of the distributor, for example. Detailed in-
formation can be found in the "USB mode" section.
In the same way as the "Common Error" function, the corresponding relay
picks up as soon as an error or warning is present.
It is possible to connect one or more suitable lamps to the relay board to in-
dicate the state of charge or the operating status of the battery charger.
Detailed information can be found in the "Signal lamp" section of the "Op-
tions" chapter.
The relay picks up continuously as soon as the battery charger is connected
to the grid.
Indicates that it is necessary to refill the battery with distilled water.
Detailed information can be found in the "Additional functions" section of
the "Display" chapter.
The settings are made as explained in section "-> Settings" for "Air Pump".