Descargar Imprimir esta página

Fronius Selectiva 4.0 Serie Manual De Instrucciones página 58

Ocultar thumbs Ver también para Selectiva 4.0 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

NOTE!
Ongoing charges are not influenced by the set time windows.
58
If a battery is connected at 05:45 in the above example, charging is stopped
when necessary and is not interrupted by the specified charge end time (6:00
in the example) of the set time window.
If the battery is connected within the stop time window, charging will start
automatically in the next time window. If a manual charge start is triggered
during the stop time window, charging always takes place with curve 1.
"Day setting 1-5":
The day settings allow up to 5 different
charge start time profiles to be
defined, with the following setting op-
tions:
-
Symbol for curve 1:
Time window within which curve 1
should be started (e.g.: 0:00–6:00)
-
Stop:
Time window within which no char-
ging should take place (e.g.: 6:00–
20:00)
-
Symbol for curve 1:
Time window within which curve 1
should be started (e.g.: 20:00–
24:00)
Additional setting options:
-
Change the assigned curve:
curve symbol.
-
Remove the curve in question:
"remove".
"Week setting":
-
It is possible to configure 3 differ-
ent week settings.
Each day of the week can be assigned
one of the previously created day set-
tings.

Publicidad

loading

Este manual también es adecuado para:

Selectiva 4.0 d1 ulSelectiva 4.0 e1 ulSelectiva 4.0 f1 ul