Danger of a residual current.
An electric shock due to a residual current can be fatal.
Risk of fire.
Fire can cause serious injury and property damage.
1)
2)
3)
4)
80
WARNING!
Only use a type B residual current circuit breaker for the grid connection of
the device.
CAUTION!
Use only on circuits that have 35 ampere auxiliary circuit protection in ac-
cordance with the National Electrical Code NFPA 70
Mains voltage (-10 % / +10 %)
Mains fuse protection
Minimum mains lead cross section
Duty cycle
EMC device class
Max. permitted grid impedance Z
3)
PCC
Safety class
4)
Degree of protection
Overvoltage category
Operating temperature
Storage temperature
Relative humidity
Maximum operating altitude above sea level
Mark of conformity
Product standard
Dimensions l x w x h
Platform
Weight (with standard grid and charging
cable)
Pollution degree
The device may be operated on grids that are grounded at the neutral
point with a maximum outer conductor voltage of 528 V.
The leakage current to earth is less than 5 mA.
Interface to a 277/480 V and 60 Hz public grid.
For indoor use only, must not be exposed to rain or snow.
1)
2)
on
max
5)
3~ NPE 480 V AC / 60 Hz
35 A
AWG 8 (8.34 mm²)
100%
B
None
1
IP 20
III
-4 °F to 104 °F
(-20 °C to +40 °C)
-13 °F to 176 °F
(-25 °C to +80 °C)
Maximum 85%
6561 ft. (2000 m)
According to rating plate
UL1564, FCC Part 15 A & B
C22.2 No. 107.2-01
30.91 x 9.72 x 15.43 in.
(785 x 247 x 392 mm)
F1
103.62 lb. (47 kg)
2