EN
tive protection against intrusion.
If effective protection is required, the automation
system must be combined with other devices;
the product may not be used until the automation
system "commissioning" procedure has been per-
formed as specified in the "Automation system te-
sting and commissioning" section;
the system power supply line must include a circuit
breaker device with a contact gap allowing com-
plete disconnection in the conditions specified by
class III overvoltage;
use unions with IP55 or higher protection when
connecting hoses, pipes or cable glands;
the electrical system upstream of the automation
system must comply with the relevant regulations
and be constructed to good workmanship stan-
dards;
this appliance can be used by children aged from
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been gi-
ven supervision or instruction concerning use of
the appliance in a safe way and understand the
hazards involved;
before starting the automation system, ensure that
there is no-one in the immediate vicinity;
before proceeding with any cleaning or mainte-
nance work on the automation system, disconnect
2 - INTRODUCING THE PRODUCT
2.1 - Technical characteristics
TECHNICAL DATA
Torque
Temporary service
Opening time 90°
Control unit
Max. number of transmitters storage
Power supply
230 Vac power supply line fuses
Standby power
Rated power
Maximum input power
Red and green light integrated
Red and green light bar
Sound pressure
Protection class
32
it from the electrical mains;
special care must be taken to avoid crushing
between the part operated by the automation sy-
stem and any fixed parts around it;
children must be supervised to ensure that they do
not play with the equipment.
ATTENTION !
Frequently examine the installation for imba-
lance where applicable and signs of wear or
damage to cables, springs and mounting.
Do not use if repair or adjustment is necessary.
ATTENTION !
Since the automation system exceeds 10 kg in
weight, it must be handled using a truck (IEC
60335-2-103:2015)
ATTENTION !
Packaging components (cardboard,
plastic, etc.), duly separated, must be pla-
ced in the appropriate bins. Device com-
ponents such as electronic boards, metal
parts, batteries, etc. must be separated
and differentiated.
For the methods of disposal, the rules in force
in the place of installation must be applied. DO
NOT DISPOSE IN THE ENVIRONMENT!
KEY AUTOMATION reserves the right to amend
these instructions if necessary; they and/or any
more recent versions are available at
www.keyautomation.com
900ALT3KF
40 Nm
50 %
1 sec
CT10324F
230 V ±10%
50-60Hz
1.6 A slow-acting
10 W
(1)
30 W
60 W
yes
no
< 70 dB(A)
IP 54
ALT4K
200 Nm
80 %
3,5 sec
6 sec / 12 sec*
CT10324
200
230 V ±10%
50-60Hz
10 W
(1)
40 W
90 W
yes
yes
< 70 dB(A)
IP 54
ALT6K
305 Nm
80 %
CT10324
230 V ±10%
50-60Hz
10 W
(1)
40 W
100 W
yes
yes
< 70 dB(A)
IP 54