REMOTE MEMORISATION OF A REMOTE CONTROL WITH A REMOTE CONTROL ALREADY MEMORISED
A transmitter can be memorised without accessing the receiver. The user needs to have a transmitter memorised
previously, after which the procedure is as described below. The remote copy procedure must be carried out in
the area served by the receiver.
1. Press the key of the new remote control to be memorised, holding it down for at least 5 seconds
2. Press the key of the old remote control to be copied (if phase 1 has been successful, the automation system
will not respond)
3. Press the key of the new remote control to be memorised, holding it down for at least 3 seconds
4. Press the key of the old remote control to be copied, holding it down for at least 3 seconds, to confirm and quit
the programming mode
N.B If no commands are given for 7 seconds, the receiver automatically quits the programming mode
6.9 - Default procedure
The default procedure will reset the system to the factory settings and, if necessary, will allow to change the motor type.
To proceed, enter the ADVANCED MENU: press and hold for 5 sec. the
until
appears. Press the
ATTENTION !
ONLY if you need to change the type of motor, change the number with
Press and hold the
(MENU) button, a countdown starts: 49, 48, ..., 1 until
6.10 - Customising the system - Basic menu
If necessary, users may select a BASIC MENU which allows modi-
fication of the control unit's basic parameters. To select the BASIC
MENU proceed as described below.
Exampling of modifying a BASIC MENU parameter
Press the
(MENU) button
for 1 second to access the ba-
sic menu.
Press the
(MENU) button for more than 1
second (LONG PRESS) to save the modified
value. The value stops flashing. Alternatively,
press the
(MENU) button QUICKLY to
quit the function without saving.
(MENU) button for 1 sec. to see the type of motor selected
After accessing the BASIC
MENU, press the
(UP)
and
(DOWN) button to
scroll through the functions.
Press the
(UP) or
tons to scroll through the functions to
modify other parameters.
(MENU) button. Scroll the menu with
(UP) or
(DOWN)
appears. Release the button.
ATTENTION !
To be certain of accessing the NORMAL OPERATION display
state, the starting point for accessing the BASIC MENU, press
the
(MENU) button twice
To access the value modifi-
cation function, press the
(MENU) button for 1 second,
until the value starts to flash
quickly.
(DOWN) but-
Press the
quit the menu.
>5s
>3s
>3s
>3s
(UP)
(DOWN-RADIO)
Press the
or
buttons to
to modify the value.
(MENU) button quickly to
EN
45