Descargar Imprimir esta página

Key Automation ALT3KF Instrucciones Y Advertencias Para Su Instalación Y Uso página 46

Automatización para barreras viales con mástil desde 3 hasta 8 m

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 86
EN
ALT4K /ALT6K BASIC PARAMETERS (CT10324)
CT10324
1
2
3
4
5
6
7
8
9
10
11
12
46
OLD
CT10224
TCL
Automatic reclosure time (0 = off)
ttr
Reclosing time after transit on PH1 (0 = off)
Sensitivity on obstacles
SEI
0 = Maximum impact force
10 = Minimum impact force
Motor speed during opening
1 = minimum
2 = low
SFO
3 = medium
4 = high
5 = maximum
Motor speed during opening deceleration phase
1 = minimum
2 = low
SSO
3 = medium
4 = high
5 = maximum
Motor speed during closing
1 = minimum
2 = low
SFC
3 = medium
4 = high
5 = maximum
Motor speed during closing deceleration phase
1 = minimum
2 = low
SSC
3 = medium
4 = high
5 = maximum
STEP BY STEP or SBS configuration:
0 = Normal (AP-ST-CH-ST-AP-ST...)
1 = Alternate STOP (AP-ST-CH-AP-ST-CH...)
SBS
2 = Alternate (AP-CH-AP-CH...)
3 = Apartment block – time (set
4 = Apartment block with immediate reclosure
Additional stop/edge input:
0 = disabled
1 = PAR input becomes STOP NO
2 = PAR input becomes STOP NC
3 = PAR input becomes EDGE NC in open
4 = PAR input becomes EDGE 8K2 in open
5 = PAR input becomes EDGE 4K1 in open
ST2
Attention: to activate EDGE2 the parameter TYPE
EDGE must be 0 (EDGE1 only when closing)
Attention: EDGE2 is connected as "Opening Edge"
and will be considerated if it is engaged during ope-
ning. It will react with a brief reversal of the barrier to
clear the obstacle.
Attention: deactivatin safety with DIP SWITCH has
no effect on this input
Deceleration distance
1 to 100 = Motor deceleration percentage during
LSI
opening and closure
P= customized decelerations
Post blackout procedure
BlT
0 = No action, remains stationery
1 = Closure
Energy saving: enables photocell switch-off when bar-
rier is closed (only during this function PHOTOTEST
SBY
is not possible)
0= disabled
1= enabled
DESCRIPTION
≠ 0)
DEFAULT
MIN
MAX
0
0
900
0
0
30
3
0
10
4
1
5
1
1
5
4
1
5
1
1
5
4
0
4
0
0
5
20
1
100
0
0
1
0
0
1
UNIT
s
s
%

Publicidad

loading

Este manual también es adecuado para:

Alt4kAlt6k900alt3kf900alt4k900alt6k