• Remove the filter/cartridge cover. Hold the filter/cartridge upside down. Pull out on the blue tab
at the bottom of the filter cover to unlatch it from the filter/cartridge. Pull the cover down and
away from the filter/cartridge.
BATTERY PACK CHARGING & INSTALLATION
Battery Pack Charge Status
Battery pack charge status is indicated by pressing the indicator button on the top of the battery (Fig.
7). Number of bars illuminated indicates approximate battery pack charge capacity (5 bars: 80-100%; 1
bar: less than 20%) based on original battery capacity.
NOTE: As the battery pack ages, it will normally lose capacity. An older battery pack, or one that has
been exposed to temperature extremes, may show less than 5 bars after completing a charge cycle
(i.e. after a full charge as indicated by the battery charger, only 4 bars light indicating 60-80% of
original capacity is available).
Install and Remove the 3M™ Versaflo™ Powered Air Purifying Respirator TR-600
Battery Packs
NOTE: Only 3M™ Battery Pack TR-630 and 3M™ Battery Pack TR-632 can be used with the 3M™
Versaflo™ Powered Air Purifying Respirator TR-600 Motor/Blower. Attempts to use any other battery
pack will void the NIOSH approval, system warranty, will not provide respiratory protection, and may
damage the PAPR. Versaflo TR-600 battery packs will not function on other PAPR systems.
To install a charged battery pack, hold the unit so the filter cover faces you (Fig. 8).
1. Inspect the hinge and latch on the battery pack and ensure it is clean and undamaged.
2. Inspect the molding surrounding the electrical connection pins. It must be in place and intact.
3. Ensure the gold electrical contact on the battery and pin area of the motor/blower are clean, dry, and
free of debris.
4. Hook the hinge end of the battery pack into its holder on the bottom of the unit (Fig. 8, step 1).
5. Push the latch side of the battery pack into the motor/blower until the latch engages with an audible
click (Fig. 8, step 2).
6. Grasp the battery pack and gently pull to confirm pack is locked into place.
To remove the battery pack, hold the unit so the filter cover faces you. Press the blue battery pack latch
and pull the battery pack down and out.