Storage conditions:
Relative humidity
Temperature (daily storage)
Temperature (extended storage)
Optimal temp for battery packs to maintain
existing charge while stored off charger
Battery charging:*
* Based on the internal temperature of the
battery
Shelf life from date of manufacture when stored
in original packaging and recommended storage
conditions:
1. Motor/blower
2. Battery pack
3. Filters and cartridges
TROUBLESHOOTING
To reduce exposure to hazardous voltage:
a. Do not attempt to service the chargers. There are no user-serviceable parts inside.
b. Do not substitute, modify or add parts to the chargers.
c. Inspect the chargers and power cords before use. Replace if any parts are damaged.
d. Do not use the chargers outdoors or in wet environments.
There are no user serviceable parts inside the 3M™ Versaflo™ Powered Air Purifying Respirator
TR-600 PAPR Assembly. The motor/blower unit should not be opened to attempt repairs. Consult
the TR-600 troubleshooting guide or contact 3M Technical Service to help identify additional
possible causes and corrective actions for other problems you may experience.
TR-600 FILTER AND CARTRIDGE OPTIONS WITH COVERS
Protection
HE
HE/HF/Nuisance OV
HE/OV
HE/OV/AG/HF
HE/Multi-gas
HE/AG
HE/Formaldehyde
HE/Ammonia/
Methylamine
W WARNING
Catalog #
TR-6710N-5 & TR-6710N-40
TR-6820N
TR-6510N
TR-6530N
TR-6590N
TR-6320N
TR-6350N
TR-6360N
< 90%
-22°F to 122°F (-30°C to 50°C)
40°F to 95°F (4°C to 35°C)
59°F (15°C)
Range: 32°F to 104°F (0°C to 40°C)
Optimal: 68°F to 77°F (20°C to 25°C)
1. 5 years (Run for 5 minutes per year)
2. 1 year
3. 5 years
California Energy Commission Compliant
Associated
Cover Size
TR-6700FC
TR-6800FC
TR-6500FC
TR-6500FC
TR-6500FC
TR-6300FC
TR-6300FC
TR-6300FC
18
Cover Size Icon on Filter/
Cartridge and on Inside of
Cover

Publicidad