4. Removal: Turn the motor/blower upside down so that the outlet faces down (Fig. 12) to help
minimize the potential for contamination of the outlet.
Fig. 11 Installing breathing tube
HEADGEAR
The 3M™ Versaflo™ Powered Air Purifying Respirator TR-600 is approved for use with many 3M™
Headgear options. Refer to the headgear User Instructions for information on attaching and donning
the headgear to be used, and to determine assigned protection factor (APF) for the complete
respiratory protection system. Consult 3M Technical Data Bulletin #175 for additional information on
APFs and supporting test data.
OPERATING INSTRUCTIONS
Power 3M™ Versaflo™ Powered Air Purifying Respirator TR-600 on:
• Press and hold the smaller, blue power button (Fig. 13-1) for 1 second. The unit will turn on and
perform a self-diagnostic. The flow level, filter loading and battery charge indictors will blink, the
auditory alarm will sound and vibratory alarm will activate. Battery indicator (Fig. 13-4) will show
current charge status of the battery pack. Filter indicator will show remaining capacity of the filter
(Fig. 13-5). Continuous blinking and/or sounding of any alarm indicates a fault condition that must
be corrected prior to use of the respirator system. If auditory, vibratory alarm or visual indicators
do not activate at start-up, do not use system. Remove from service and see your supervisor.
Select airflow:
• There are three user selectable airflow settings: standard, medium, and high flow. The motor/blower
will start at the standard flow setting. Pressing and holding the larger blue flow control button (Fig.
13-2) for 1 second will cycle the motor/blower to the next of three flow settings. One beep and flow
LED on the flow setting indicator (Fig. 13-3) indicates standard flow, two beeps and two flow LEDs
indicate medium flow, three beeps and three flow LEDs indicate high flow. Pressing the flow control
button once more cycles back to the standard flow setting.
Power 3M™ Versaflo™ Powered Air Purifying Respirator TR-600 off:
• Press and hold the smaller, blue power button for 2 seconds (Fig. 13-1).
2
1
Fig. 13 Motor/blower User Interface
Display Sleep Mode
To conserve battery power, the display will go into 'sleep mode' after 30 seconds from the last button
press. The flow speed indicator will periodically blink with the current flow setting (Fig. 13-3). To wake
up the display, momentarily press any display button.
3
4
Fig. 12 Removing breathing tube
6
5
1) On/Off button
2) Flow control button
3) Airflow setting indicator
4) Battery charge status level/
5) Filter loading/alarm indicator
6) Tight-fitting mode indicator
11
alarm indicator
(future option)

Publicidad

loading