Wiring Plan M12 X 1 Plug Connector - Balluff BMD 1H Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Electronics and terminal
compartment
4...20mA
+
( )
1
Fig. 12: Electronics and terminal compartment - single chamber housing
1
Voltage supply, signal output
2
For display and adjustment module or interface adapter
3
For external display and adjustment unit
4
Ground terminal for connection of the cable screen
5.4

Wiring plan M12 x 1 plug connector

The illustration shows the structure and the assigned pins of the plug
connector. The table shows the assignment of the individual contact
pins to the terminals of the sensor electronics.
1
2
Voltage supply/Signal output
Contact
Colour, connection ca-
pin
ble in the sensor
1
Green
2
Free
3
Black
4
Red
5 Connecting to power supply
1
2
5
6 7 8
(-)
Terminal, elec-
tronics module
Free
Terminal 2
Terminal 1
2
3
4
4
3
Function/Po-
larity
Screen
Free
Power supply/-
Power supply/+