6
Description of connections
To access the control connection terminal board, remove the motor cover as shown in gure 1:
Figure 2-3-4-5 shows connection diagrams for connecting mains voltage to the motor control unit
6.1
Typical installation
2
7
1
8
1
Power supply
2
Photocell - Receiver F4ES/F4S
3
Photocell - Transmitter F4ES/F4S
Flashing light R92/LED24 - FIFTHY/24
4
Power supply 24Vdc LED (25 W max, power consumption 50%)
5
Antenna
Key selector R85/60
6
Key pad H85/TTD - H85/TDS (connecting to control panel to
decoder board H85/DEC - H85/DEC2)
Gate open indicator
7
Power supply 24V DC 3W max
Courtesy light (Potential free contact)
8
Power supply 230 Vac (100 W max)
SUGGESTIONS: with existing installations, we recommend checking the cross section of the cables and
that the cables themselves are in good condition.
5
4
3
Recommended cable
H07RN-F 3x1,5 mm
Cable 4x0,5 mm
Cable 2x0,5 mm
Cable 2x1 mm
Cable 50 Ohm RG58 (max 10 m)
Cable 3x0,5 mm
Cable 3x0,5 mm
Cable 2x0,5 mm
Cable 2x1 mm
.
6
2
3
double insulated cable
2
(max 20 m)
2
(max 20 m)
2
(max 10 m)
2
(max 20 m)
2
(max 20 m)
2
2
(max 20 m)
(max 20 m)
2
57