9.4 CONNECTION TO THE WATER SUPPLY

The appliance must be connected to a potable water supply.
• Install a mechanical filter and a shut-off valve upstream of the
appliance in an easily accessible point.
• Make sure the water circuit is free from ferrous particles befo-
re connecting the filter and the appliance.
• Seal any unused connectors with a plug.
• Once the appliance has been installed, check for leaks at the
connection points.
• Hot water connection: the water temperature must not exceed
60°C.
The water inlet pressure must be between 150 kPa and 300
kPa. Use a pressure reducer if the inlet pressure is above the
maximum permitted level.
9.5 CONNECTION TO THE WATER DRAIN
The water drainage system must be provided using materials
resistant to temperatures of 100 °C. The bottom of the applian-
ce must not be subjected to steam produced by drainage of
hot water. Install a siphoned floor drain with grating below the
water drain cock of Boiling pans and in front of Bratt pans.
10
PANS WITH AUTOCLAVE LID
While the appliance is operating with the lid closed, check the
functioning of the automatic valve decompression rod by pres-
sing the black button. Also check that the steam discharge hole
is open.
Valve operating pressure: 5kPa (0,05bar).

11 CONVERSION TO A DIFFERENT TYPE OF GAS

Table T1 specifies, for each country:
• which gas can be used for the appliance.
• the nozzles and settings foreach gas that can be used.For
nozzles, the number indicated in table T1 is also stamped on
the nozzle body.
To convert the appliance to the local gas type, follow the in-
structions given in atable T1 and carry out the steps below:
• Replace the main burner nozzle ( UM ).
• Adjust the main burner's air regulator to distance A.
• Replace the pilot burner nozzle ( UP ).
• Adjust the pilot burner air flow (if necessary).
• Replace the gas valve minimum nozzle ( Um ).
• Affix the adhesive tab indicating the new type of gas used.The
nozzles and adhesive tabs are supplied with the appliance.
11.1 REPLACING THE MAIN BURNER NOZZLE AND ADJU-
STING THE PRIMARY AIR FLOW.
• Remove the front panel
• Remove nozzle UM and replace it with the one indicated in
table T1.
• Retighten nozzle UM.
• Slacken screw V and position the air regulator at distance A
as indicated in table T1.
• Retighten screw V fully.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.

11.2 REPLACING THE PILOT BURNER NOZZLE

• Remove the front panel
• Undo connector R.
• Remove nozzle UP and replace it with the one indicated in
table T1.
• Retighten the connector R. Re-assemble all parts.
• For assembly, proceed in reverse order.

12 COMMISSIONING

See Chapter " INSTRUCTIONS FOR MAINTENANCE".

INSTRUCTIONS FOR USE

REMINDERS FOR THE USER

The manufacturer will not be liable for
any damage or injury resulting from fai-
lure to observe the following rules.
• Read this manual carefully. It provides im-
portant information for safe installation,
use and maintenance of the appliance.
• Keep this manual in a safe place known to
all users so that it can be consulted throu-
ghout the working life of the appliance.
• Installation, conversion to a different type
of gas and appliance maintenance must
be carried out by qualified technicians au-
thorized by the manufacturer, in complian-
ce with current safety standards and the
instructions given in this manual.
• For after-sales service, contact technical
assistance centers authorized by the ma-
nufacturer and demand the use of original
spare parts.
• Have the appliance serviced at least twice
a year. The manufacturer recommends ta-
king out a service contract.
• The appliance is designed for professional
use and must be operated by trained per-
sonnel.
• The appliance is to be used for cooking
food as specified in the prescriptions for
use. Any other use is considered to be im-
proper.
• Do not allow the appliance to operate emp-
ty for prolonged periods. Only pre-heat the
oven just before use.
• Do not leave the appliance unattended
while in operation.
• In the event of an appliance fault or mal-
function, shut the gas shut-off valve and/or
switch the appliance off at the main switch
installed upline.