Festo EasyPort USB Manual De Instrucciones página 148

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9. EasyPort USB command interpreter
Command
Response
DEW<n>.2
EW<n>.2=xxxx
where xxxx =
0000...7FF8
DEW<n>.4
EW<n>.4=xxxx
where xxxx =
0000...7FF8
DEW<n>.6
EW<n>.6=xxxx
where xxxx =
0000...7FF8
DEW<n>.8
EW<n>.8=xxxx
where xxxx =
0000...7FF8
Reading in analogue input signals
148
148
Description
Read in input channel 0
Values at input channel 0 are read in at the EasyPort USB
module with address <n> (<n> = 1...4).
Example
DEW1.2
Read in input channel 0 at the EasyPort USB module with
address 1.
Read in input channel 1
Values at input channel 1 are read in at the EasyPort USB
module with address <n> (<n> = 1...4).
Read in input channel 2
Values at input channel 2 are read in at the EasyPort USB
module with address <n> (<n> = 1...4).
Read in input channel 3
Values at input channel 3 are read in at the EasyPort USB
module with address <n> (<n> = 1...4).
© Festo Didactic GmbH & Co. KG „ 721876