6. Commissioning

© Festo Didactic GmbH & Co. KG „ 721876
You'll need the following to commission the EasyPort USB:
The EasyPort USB
A 24 V DC power supply unit
A PC, if you want to evaluate data from the EasyPort USB using a PC
The EasyPort CD ROM for installing the USB drivers on the PC
The USB cable
The following items are also helpful:
The EasyPort demo application for quickly and easily establishing a
connection with the EasyPort USB
A simulation box, which makes it easy to generate process signals
for the EasyPort USB
Procedure
1. Connect the EasyPort USB to a 24 V DC power supply using the 24 V
DC connecting cable with 4 mm safety plugs.
2. Switch on the power supply for the EasyPort USB.
‟ The red error LED lights up briefly. It switches off again during the
start-up test.
‟ The green status LED flashes at a frequency of 1 Hz.
This means that the EasyPort USB is not yet communicating.
3. After the start-up test has been completed, EasyPort USB is ready
for operation and waits to be initialised by the PC. The address
selected with the help of the scroll buttons is used for this.
4. Check the address of the EasyPort USB.
‟ Activate the address setting mode by pressing both scroll buttons
simultaneously.
‟ Select an address within a range of 1...4 with the scroll buttons.
‟ Exit the address setting mode by simultaneously pressing
both scroll buttons.
5. Connect the EasyPort USB to the PC using the USB cable included.