3. Technical data
Technical data for EasyPort USB, general (continued)
3.2
SysLink interface
for digital data
100
100
EasyPort USB D16A process interface
Protection
CE mark
Permissible ambient
temperature,
operation/storage
Dimensions in mm
(L x W x H)
Weight in kg
Each set of 8 digital inputs and outputs is connected to a SysLink 24-pin
socket connector at the EasyPort USB in accordance with IEEE 488. In
addition, input 0 at ports 1 and 2 can be used as high-speed counter
inputs. The counter inputs can be operated with voltage levels ranging
from 5 to 24 V DC.
IP 20
Per EU/EMC directive
0...55° C/0...70° C
135 x 167 x 37
0,65
© Festo Didactic GmbH & Co. KG „ 721876