9. EasyPort USB command interpreter
Command
Description
MF<n>=01
Force analogue input channel 0
Measured values from analogue input channel 0 are displayed on the LCD of the EasyPort
USB module with address <n> (<n> = 1...4).
MF<n>=02
Force analogue input channel 1
Measured values from analogue input channel 1 are displayed on the LCD of the EasyPort
USB module with address <n> (<n> = 1...4).
MF<n>=04
Force analogue input channel 2
Measured values from analogue input channel 2 are displayed on the LCD of the EasyPort
USB module with address <n> (<n> = 1...4).
MF<n>=08
Force analogue input channel 3
Measured values from analogue input channel 3 are displayed on the LCD of the EasyPort
USB module with address <n> (<n> = 1...4).
MF<n>=10
Force analogue output channel 0
Measured values from analogue output channel 0 are displayed on the LCD of the
EasyPort USB module with address <n> (<n> = 1...4).
MF<n>=20
Force analogue output channel 1
Measured values from analogue output channel 1 are displayed on the LCD of the
EasyPort USB module with address <n> (<n> = 1...4).
MF<n>=00
Disable analogue channel forcing
Measured values from the analogue channel which is selected directly at the EasyPort
USB using the scroll buttons are once again displayed on the LCD panel of the EasyPort
USB module with address <n> (<n> = 1...4).
Forcing analogue channel display on the LCD
© Festo Didactic GmbH & Co. KG „ 721876
151