12. IEC 60601-1-2 and IEC 60601-1-11

The ARTROMOT®-E2/-E2 compact device
is subject to particular precautions regard-
ing electro magnetic compatibility (EMC).
The device must be installed and put into
service strictly in compliance with the EMC
directives set forth in the accompanying
documents.
Portable and mobile RF communication
systems may affect the ARTROMOT®-E2/
-E2 compact.
TheARTROMOT®-E2/-E2 compact should
not be used adjacent to or stacked with
other equipment. If adjacent or stacked
use is necessary, ARTROMOT®-E2/-E2
compact should be observed to verify
normal operation in the configuration in
which it will be used.
If you detect damage or malfunctions that
may impair the safety of the patient or
of the operator, have the device repaired
before using it.
WARNING!
m
Use of accessories, transducers and cables other than those specified or provided by the
manufacturer of this equipment could result in increased electromagnetic emissions or
decreased electromagnetic immunity of this equipment and result in improper operation.

12.1 Electromagnetic emissions

Guidance and Manufacturer's Declaration – Electromagnetic Emissions
ARTROMOT®-E2/-E2 compact is intended for use in the electromagnetic environment
specified below. It is the responsibility of the customer or user to ensure that the
ARTROMOT®-E2/-E2 compact unit is used in such an environment.
Emissions test
RF emissions to CISPR 11
RF emissions to CISPR 11
Harmonic emissions to
IEC 61000-3-2
Voltage fluctuations/flicker
emissions to IEC 61 000-3-3
If it is necessary to replace assemblies or
cables, only the manufacturer's original
parts must be used to ensure continued
compliance with EMC requirements after
repair. This requirement applies to the
power supply unit, cables and cable lengths,
drive unit consisting of the motor and the
control system, the programming unit incl.
the coiled cable and the connector.
Regarding the electromagnetic compatibi-
lity, there is no maintenance work required
during the expected service life of the
product.
The product designation ARTROMOT®-E2/
-E2 compact used in the text below in-
cludes all product variants.
Compliance
Electromagnetic environment –
guidance
ARTROMOT®-E2/-E2 compact uses
Group 1
RF energy only for its internal func-
tion. Therefore, its RF emissions are
very low and are not likely to cause
any interference in nearby electronic
equipment.
ARTROMOT®-E2/-E2 compact is
Class B
suitable for use in all establishments,
not applicable
including domestic and those directly
connected to the public low-voltage
power supply network that supplies
not applicable
buildings used for domestic purposes.