Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 235
106
AVENTICS | Bus Coupler AES/Valve Driver AV, PROFINET IO | R412018140–BAL–001–AG
Conversion of the Valve System
28
29 30 43
20
AES-
D-BC-
PNIO
UA
P
Fig. 16: Creating sections with two pneumatic supply plates and one electrical supply plate
12.5.1

Sections

The valve zone of a valve system can consist of multiple sections. A section always starts with
a supply plate that marks the beginning of a new pressure or voltage zone.
An UA-OFF monitoring board should only be installed after an electrical supply plate, otherwise
the actuator voltage UA is monitored before supply.
24
22
23
30
P
S1
28 Bus coupler
29 Transition plate
30 Pneumatic supply plate
43 Long bridge card
20 Base plate, 2x
21 Base plate, 3x
24 Valve driver board, 4x
22 Valve driver board, 2x
23 Valve driver board, 3x
44 Short bridge card
The valve system in Fig. 16 consists of three sections:
Table 28:
Example valve system, consisting of three sections
Section
Section 1
Section 2
Section 3
44
42
41
AV-EP
(M)
A
S2
Components
Pneumatic supply plate (30)
Three base plates, 2x (20), and one base plate, 3x (21)
Valve driver boards, 4x (24), 2x (22), and 3x (23)
9 valves (61)
Pneumatic supply plate (30)
Four base plates, 2x (20)
Two valve driver boards, 4x (24)
8 valves (61)
AV-EP base plate for single pressure control
AV-EP pressure regulator
Electrical supply plate (35)
Two base plates, 2x (20), and one base plate, 3x (21)
Supply plate (38), 4x valve driver board (24) and 3x valve driver board (23)
7 valves (61)
35
38
61
UA
42 Valve position for pressure regulator
41 Integrated AV-EP circuit board
35 Electrical supply plate
38 Electrical supply board
61 Valve
S1 Section 1
S2 Section 2
S3 Section 3
P Pressure supply
A Single pressure control working connection
UA Power supply
S3

Publicidad

Tabla de contenido
loading

Tabla de contenido