AVENTICS | Bus Coupler AES/Valve Driver AV, PROFINET IO | R412018140–BAL–001–AG
Table 20:
14
Designation
UL
15
UA
UL (14)
16
IO/DIAG
RUN/BF
UA (15)
17
L/A 1
IO/DIAG (16)
L/A 2
18
RUN/BF (17)
19
L/A 1 (18)
L/A 2 (19)
1)
At least one of the two LEDs L/A 1 and L/A 2 must be illuminated in green or be illuminated in green and flash quickly
in yellow. Depending on the data exchange, the flashing may be so fast that it appears that the LED is illuminated. The color
then appears to be light green.
If the diagnostic run is successful, you may commission the valve system. Otherwise, the errors
must be remedied (see section 13 "Troubleshooting" on page 110).
3. Switch on the compressed air supply.
Status of the LEDs on commissioning
Color
State
Green
Illuminated
Green
Illuminated
Green
Illuminated
Green
Illuminated
1)
Yellow
Flashes quickly
1)
Yellow
Flashes quickly
Commissioning the Valve System with PROFINET IO
Meaning
The electronics supply voltage is greater than the lower
tolerance limit (18 V DC).
Actuator voltage exceeds the lower tolerance limit (21.6 V DC).
The configuration is OK and the backplane is working perfectly.
The bus coupler exchanges cyclical data with the controller.
Connection with Ethernet device on fieldbus connection X7E1
Connection with Ethernet device on fieldbus connection X7E2
93