A B B I N D U S T R I A L D R I V E S D C S 8 8 0 Q U I C K G U I D E
A B B I N D U S T R I A L D R I V E S D C S 8 8 0 Q U I C K G U I D E - 3 A D W 0 0 0 5 4 5 R 0 2 0 0

Parameter groups

Summary of parameter groups
Group
01 Actual values
03 Input references
04 Warnings and faults
05 Diagnostics
06 Control and status words
07 System info
10 Standard DI, RO
11 Standard DIO, FI, FO
12 Standard AI
13 Standard AO
14 I/O extension module 1
15 I/O extension module 2
16 I/O extension module 3
19 I/O Operation mode
20 Start/Stop/Direction
21 Start/Stop mode
22 Speed reference selection
23 Speed reference ramp
24 Speed reference conditioning
25 Speed control
26 Torque reference chain
27 Armature current control
28 EMF and field current control
29 12-pulse/Hardparallel
30 Control limits
31 Fault functions and fault levels External events, tripping level.
32 Supervision
33 Generic timer & counter
35 Motor thermal protection
36 Load analyzer
37 User load curve
40 Process PID
42 Shared motion (2nd motor)
44 Mechanical brake control
45 Energy efficiency
46 Monitoring/Scaling settings

Control loops most wanted signals

Optimization of control loop requires comparison of reference and actual values
Input signals
10.01 DI status
12.11 AI1 actual value
12.21 AI2 actual value
Contents
Volt, Amps, rpm.
Fieldbus, D2D.
Run-time-type counters, bridge
temperature.
Control status words.
Hardware and firmware information.
Digital inputs, relay outputs.
Analog inputs.
Analog outputs.
Speed/torque selection.
Digital input, Main control word
Ramp, coast.
Analog input, fieldbus
Drive operation limits.
Maintenance.
Temperature measurement, load
curve definition.
Speed supervision settings, signal
filtering and general scaling settings.
b0 digital input DI1
b1 digital input DI2
b2 digital input DI3
b3 digital input DI4
b4 digital input DI5
b5 digital input DI6
b15 digital input DIL
analog input
analog input
Group
47 Data storage
49 Panel port communication
50 Fieldbus adapter (FBA)
51 FBA A settings
52 FBA A data in
53 FBA A data out
54 FBA B settings
55 FBA B data in
56 FBA B data out
58 Embedded fieldbus
60 DDCS Communication
61 D2D and DDCS transmit data
62 D2D and DDCS receive data
70 DCSLink Communication
74 ... 89 Application specific
groups
90 Feedback selection
91 Encoder module settings
92 Encoder 1 configuration
93 Encoder 2 configuration
94 OnBoard speed feedback
configuration
95 HW configuration
96 System
99 Motor data
Speed control loop
23.03 Speed reference 7
90.01 Motor speed for control
Armature current control loop
27.02 Used current reference
27.05 Motor current
Contents
Data storage parameters that can be
written to and read from using other
parameters' source and target
settings.
Local time out.
Fieldbus communication
configuration.
Fieldbus adapter A.
Data sent to fieldbus adapter A to the
master (e.g. PLC).
Data read from fieldbus.
Fieldbus adapter B.
Data sent to fieldbus.
Data read from fieldbus.
D2D + DDCS port.
Defines the data sent from the drive
to the DDCS/D2D link.
Defines the data sent from the DDCS/
D2D link to the drive.
External extension, 12-pulse
Analog tacho, encoder ...
Configuration of the encoder
interface modules.
FENxx
FENxx
CON-H01 analog tacho and OnBoard
encoder.
e.g. Type code
Language selection; access levels;
macro selection; parameter save and
restore; control board reboot; user
parameter sets; unit selection; data
logger triggering; parameter; user
lock.
Motor settings, autotuning
speed reference ramped
speed feedback
actual value