Acceleration Duration During Opening Movement; Acceleration Duration During Closing Movement; Nominal Speed During Opening Movement; Nominal Speed During Closing Movement - Roger Technology AG/CTRL AGILIK Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
33 04

Acceleration duration during opening movement

34 04

Acceleration duration during closing movement

01
10
01 quick start ... 10 very slow start
-
8-
NOTE: parameters
01
A low value (
) implies a quick acceleration, a high value (
a high value, the maximum speed of the barrier may be limited.
These parameters can be changed even if the stroke has already been set.
NOTE: the available values can be limited by choosing the par. A1:
40 04

Nominal speed during opening movement

41 04

Nominal speed during closing movement

01
10
01 = 10% ... 10 = 100%, maximum speed
-
NOTE: the available values can be limited by choosing the par. A1:
42 01

Slow approaching speed towards the stop

01
10
01 = 10 RPM ... 10 = 100 RPM
-
It establishes the speed of the motor while approaching the opening/closing stop; the duration of this phase
is determined by the values set for par.
43 10

Approach distance to the opening stop

44 10

Approach distance to the closing stop

01
30
tenths of one mechanical revolution of the engine at a speed set in par.42
-
NOTE: the available values can be limited by choosing the par. A1:
Attempts of automatic closing after the intervention of the safety edge or of the anti-
49 00
crushing device
00
no automatic closing after the intervention of the safety edge or of the anti-crushing device
01
03
number of closing attempts
-
If the value exceeds the one set in parameter
a2
parameter
.
50 00

Mode if photocell FT is interrupted while opening

00
IGNORE, no action or FT1 not installed
01
STOP, the door stands still until the next command
02
QUICK REVERSE, closes
03
TEMPORARY STOP, the opening movement continues even if the beam is not engaged
04
REVERSE WHEN DISABLED, if the beam is not engaged, the closing movement starts
34
b-
and
in simplified mode.
43
and
10
) implies a slower acceleration. By choosing
44
.
a2
, it will automatically be considered equal to the value of

Publicidad

Tabla de contenido
loading

Tabla de contenido