Mode If Photocell Ft Is Interrupted While Closing; If The Barrier Is Closed, The Opening Movement Is Allowed Even If Ft Is Engaged; If The Barrier Is Completely Open, It Closes After 6 Seconds From The Moment; In Which The Photocell Is Engaged - Roger Technology AG/CTRL AGILIK Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
51 02

Mode if photocell FT is interrupted while closing

00
IGNORE, no action or FT1 not installed
01
STOP, the door stands still until the next command
02
QUICK REVERSE, opens
03
TEMPORARY STOP, the closing movement continues even if the beam is not engaged
04
REVERSE WHEN DISABLED, if the beam is not engaged, the opening movement starts
52 01

If the barrier is closed, the opening movement is allowed even if FT is engaged

00
does not allow the opening movement
01
opening movement enabled
02
OPEN WHEN ENGAGED
If the barrier is completely open, it closes after 6 seconds from the moment in which the
56 00
photocell is engaged
00
OFF (the interruption of the photocell triggers no action)
01
the interruption of the photocell generates the closing movement
NOTE: this parameter is not available if the parameters
65 08

Brake regulation

01
10
01 sudden braking ... 10 soft braking
-
The brake is applied when reversing due to user commands, or to intervention of the photocells; does not
apply in the case of intervention of the safety edge, of the anti-crushing device or of the STOP (because in
these cases is used and instantaneous brake).
By setting this parameter to a low value, the braking distance is reduced to a minimum; by setting this
parameter to a high value, a "soft-stop" will be obtained, this being very useful for the 4m barriers or longer,
avoiding sudden shocks and vibrations.
Make sure that the adjustment does not cause an excessive stop movement, that may generate a risk of
collision.
71 01

Position of the barrier body in relation with the passage

00
placed to the left, watching the passage from the inside
01
placed to the right, watching the passage from the inside
-
NOTE: parameter
73 00

Safety edge Configuration

00
Not present
01
SWITCH, inverts only while closing
02
8k2, inverts only while closing
in standard mode.
A8  03
A8  04
or
are set.
35

Publicidad

Tabla de contenido
loading

Tabla de contenido