Automatic Closing After Blackout; Step-By-Step (Pp) Setup; Pre-Flashing; Shared Function On The Pedestrian Command (Ped) - Roger Technology AG/CTRL AGILIK Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
A3 00

Automatic closing after blackout

00
OFF (closing procedure will not be performed after restoring the power supply)
01
ON (closing procedure will be performed after restoring the power supply)
3-
NOTE: parameter
If this parameter is set to
flashing (even if parameter
the closing process as it ensures that the barrier gets closed after power supply restoration.
A4 00

STEP-BY-STEP (PP) setup

00
OPEN - STOP - CLOSE - STOP - OPEN
01
PP SHARED, when completely open, the command PP renews the pause time
02
PP SHARED, when completely open, the command PP closes
03
OPEN - CLOSE - OPEN - CLOSE
04
OPEN - CLOSE - STOP - OPEN
6-
NOTE: parameter
Shared means that during the opening process, the command PP is ignored.
In installations where there is the possibility that multiple users arrive at the same time, and therefore
activate the remote control while the barrier is being handled, it is useful to ensure the completion of the
opening: prevents two activations by two different users that may cause the barrier to close.
WARNING: by setting the shared mode (value
activated (parameter
By setting the parameter to
trigger the closing process; it will reset the standby time counter.
A5 00

Pre-flashing

00
OFF (the flashing light is active only when there is movement)
01
10
DURATION IN SECONDS of flashing light activation before the movement
-
99
not performed during opening procedure; 5 seconds of pre-flashing before closing
5-
NOTE: parameter
A6 00

Shared function on the pedestrian command (PED)

00
OFF (pedestrian command performs OP-ST-CL-ST-OP- ...)
01
ON (pedestrian command activated while the opening process is ignored)
A7 00

Man present

00
OFF (the commands function normally)
01
ON (the door moves only if keys OP or CL are kept pressed)
The motor remains active only if there is a continuous command active; the only enabled commands are OP
and CL; when the command is released, the motor stops.
Controls should be located in order to enable visual check of the barrier.
32
in standard mode
01
at power-up, the control unit performs the closing procedure after a 5 sec pre-
A5
disabled). This function is useful when the supply voltage is missing during
in standard mode
A2
).
01
, if the barrier is closed, the activation of the step-by-step command will not
in standard mode
01
02
and
) the automatic closing will be automatically

Publicidad

Tabla de contenido
loading

Tabla de contenido