standard or extended (advanced level).
In the extended configuration, the installer may
change a large number of parameters, but more
accurate knowledge of the product is required.
The standard configuration was designed to facilitate
the installation; there is only a reduced number of
parameters that can be changed, satisfying the most
of the installations. This is a recommended mode for
an installer that is unfamiliar with the product and
when no particular configurations are required.
WARNING!
The product leaves the factory with the standard
configuration
If you want to switch to the extended mode, keep
both keys UP and DOWN pressed for 4 seconds;
then on the display will appear the first one of the
extended version parameters, that is indicated:
• by the presence of two decimal points on the first
two digits on the left (that represent the number
of the parameter)
A
• by letter
for parameters lower than 10, to
distinguish them from the ones corresponding to
the standard configuration (that are different)
NOTE: the operation can be performed more than
once, switching from one configuration to another.
The table in paragraph 10 contains the parameters
corresponding to the extended configuration.
NOTE: the sequence of the parameters in the
simplified configuration is not the same as the
one corresponding to the extended configuration;
therefore, always consult the instructions.
5.3

Standby mode

After 30 minutes of inactivity, the control unit enters
in standby mode, and on the display will appear only
28

STANDARD CONFIGURATION

Keep pressing
the button for 4 sec.
EXTENDED CONFIGURATION
a blinking point.
The activation of the standby, automatically restores
the standard configuration.
This mode keeps the display in standby, but
the control unit is always ready to perform the
commands; in order to restart the display, one of
the keys UP,DOWN,+,- should be pressed.
5.4

TEST mode

It can be activated by pressing the key TEST, only if
the motors are shut down; otherwise, the TEST key
performs a STOP command; in order to enable the
test mode, you must press this key once again.
The display is as follows:
name of the active input
(displayed for 5 seconds)
AP
CH
PP
PE
Or
It allows to visually check the activation of the
command and of the safety devices: every time
they are activated, the control unit shortly activates
the flashing light as well as the Open Door Light
(terminal no. 11, SC).
On the display is indicated:
• the active command, as a stationary message (on
the left side, for 5 seconds)
• the terminal block number of the safety device
in alarm, as a blinking number (on the right side,
displayed as long as the safety device is in alarm).
If no other safety device is in alarm, the code
displayed and the control unit is enabled to perform
the commands.
After 10 seconds of inactivity, it returns to safety
devices and commands status. In order to exit the
test mode, just press TEST. The output SC returns to
its standard function.
6

Installation

The stroke length must be programmed to allow
proper functioning of the control unit.
terminal block number of
the safety in alarm (flashing,
displayed until alarm clear)
Maximum
21 = ST/release/
inspection door
Priority
23 = COS
Minimum
24 = FT
Priority
00
is