Impact force level motor

01
10
low torque motor : 1 minimum impact force ... 10 maximum impact force
-
11
19
medium torque motor : 11 minimum impact force ... 19 maximum impact force
-
20
Maximun torque motor : without any adjustment of the anti-crushing protection
NOTE: parameter
In order to fall within the limits of impact forces, usually use the values from
to be performed at each installation. The values from
11-19
are not adequate. The value
The torque values of low and medium engine can be modified by acting on the parameter
If the setting of parameter
the reaction time is however too long, reduce the value of parameter
34 04

Acceleration when starting motor

01
05
1 = quick start ... 05 = very slow start
-
A low value (
speed more slowly, thus allowing a more gentle and gradual start of the wing.
NOTE: these parameters can be changed even after you have programmed the stroke.
40 05

Rated speed

01
05
1 = minimum speed ... 5 = maximum speed
-
01
The values
maximum speed.
49 00
Automatic reclosing attempts after safety edge or the anti-crushing protection intervention
00
does not automatically reclose after the safety edge or the anti-crushing protection intervention
01
03
number of attempts at reclosing
-
If the value exceeds that of parameter
a2
parameter
(check the value of parameter 27).
50 00

Mode if photocell FT1 is interrupted when opening

00
IGNORE, no action or FT1 not installed
01
STOP, the gate remains stationary until the next command
02
REVERSE IMMEDIATELY, thus closing
03
TEMPORARILY STOP, the beam released, it continues to open
04
INVERT WHEN RELEASED, the beam released, it reverses thus closing
51 02

Mode if photocell FT1 is interrupted when closing

00
IGNORE, no action or FT1 not installed
01
STOP, the gate remains stationary until the next command
02
REVERSE IMMEDIATELY, thus closing
03
TEMPORARILY STOP, the beam released, it continues to open
04
INVERT WHEN RELEASED, the beam released, it reverses thus closing
34
b-
in simplified mode
31
causes the impact to be too hard, try decreasing parameter
01
) involves rapid acceleration, while a high value (
02
03
04
-
-
-
-
. Only recloses after the impact if it is moved back until fully open.
01
20
should be used only in the presence of sensitive edges.
05
respectively correspond 60%, 70%, 80%, 90% e 100% of the
a2
, it will be automatically considered to be equal to that of
11
10
to
are to be used only in case the values
31
.
05
) means reaching the operating
19
to
; the check is
30
.
30
. If