01= the gate decelerates near stops and the limit switch (if installed).
...
05= the gate decelerates long before stops and the limit switch (if installed).
Adjusting LEAF 1 position control when completely opens or closes
mechanical stop. The position of LEAF 1 is calculated by the system from the number of motor revolutions and the
motor reduction gear ratio.
Warning! Excessively low values cause the gate to reverse when it reaches the gate open stop.
N.B.
BR21 automation systems, with the gate leaf in the completely closed position, adjust the inner mechanical
stop so that the lever of the gear motor can move by a few millimetres.
Adjusting LEAF 2 position control when completely opens or closes
mechanical stop. The position of LEAF 2 is calculated by the system from the number of motor revolutions and the
motor reduction gear ratio.
Warning! Excessively low values cause the gate to reverse when it reaches the gate closed stop.
N.B.
BR21 automation systems, with the gate leaf in the completely closed position, adjust the inner mechanical
stop so that the lever of the gear motor can move by a few millimetres.
Motor revolutions (

Partial opening adjustment (%)

N.B.: with double leaf swing gate installations, this parameter is set by default as the completely open position of
LEAF 1.
With single leaf swing gate installations, this parameter is set to 50% of total opening.
From 15% to 99% of total gate travel.
Type of signaling provided by COR output
STANDARD operation managed by parameter
Contact closed if the control unit is working properly.
Contact open if central locked in alarm.
Contact closed if the control unit is powered by the mains or charged battery.
(the control unit no longer accept commands).
Closed contact if none of the fault related situations 1 and 2 occurs.
Open contact if at least one of the fault related situations 1 and 2 occurs .
Closed contact if the gate is not completely open.
Open contact if the gate is completely open.
Closed contact if the gate is not completely closed.
Open contact if the gate is completely closed.
Adjusting stop advance of LEAF 1 when opening
Adjusting stop advance of LEAF 2 when opening
The leaf stops against the opening stop.
A leaf stop advance of 1 to 25 motor turns before the completely open position may be set.

Setting automatic closing time

The timer starts from the gate open state and continues for the set time. Once the set time is reached, the gate closes
automatically. The timer count restarts if a photocell is triggered.
IMPORTANT
count is resumed when the opening command is released.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.

Enabling of management for opening with automatic reclosure exclusion

If enabled, the exclusion of automatic reclosure only applies for the command selected via the parameter. For example:
if you set
command.
NB:
Disabled.
An AP (opening) command activates the opening manoeuvre. With the gate fully open, automatic reclosure is excluded.
An AP (open) or CH (close) command activates the closure manoeuvre.
70
= maximum).
, automatic reclosure is excluded following an AP command, but it is activated following a PP or PED
) or with error alert